CONSTRUCTION OF A TRANSFORM-LIMITED PICOSECOND TIME-RESOLVED RAMAN SPECTROMETER

被引:43
作者
IWATA, K
YAMAGUCHI, S
HAMAGUCHI, H
机构
[1] Molecular Spectroscopy Laboratory, Kanagawa Academy of Science and Technology, Kawasaki 213
关键词
D O I
10.1063/1.1143951
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A pump-probe picosecond time-resolved Raman spectrometer has been constructed using a dye laser synchronously pumped by a cw mode-locked Nd:YAG laser and a high repetition rate (2 kHz) dye amplifier pumped by the frequency doubled output from a cw Nd:YAG regenerative amplifier. Transform-limited picosecond pulses with 3.5 cm-1 wave number width and 3.2 ps temporal width are obtained at the wavelength of 588 nm. The second harmonic of these pulses is generated at 294 nm and is used for pumping, while the remaining visible pulses are used for probing. resonance Raman scattering. The cross-correlation time between the pump and probe pulses is 4.1 ps. The temporal profile of the laser pulse is found to be very close to the sech2 shape. The wave number resolution of the system is estimated to be 3.5 cm-1 according to the Tailor criterion. The time resolution is estimated to be 2.2 ps using a criterion newly proposed in the present paper. Time-resolved Raman spectra of S1 trans-stilbene and S1 p-terphenyl are presented to demonstrate the capability of the constructed spectrometer.
引用
收藏
页码:2140 / 2146
页数:7
相关论文
共 27 条
[1]   PICOSECOND TIME-RESOLVED RESONANCE RAMAN-SPECTROSCOPY OF THE INITIAL TRANS TO CIS ISOMERIZATION IN THE BACTERIORHODOPSIN PHOTOCYCLE [J].
ATKINSON, GH ;
BRACK, TL ;
BLANCHARD, D ;
RUMBLES, G .
CHEMICAL PHYSICS, 1989, 131 (01) :1-15
[2]   PICOSECOND RAMAN MEASUREMENTS OF ELECTRON-TRANSFER IN THE METAL-TO-LIGAND CHARGE-TRANSFER EXCITED-STATES OF 1,10-PHENANTHROLINE RUTHENIUM(II) COMPLEXES [J].
CHANG, YJ ;
XU, XB ;
YABE, T ;
YU, SC ;
ANDERSON, DR ;
ORMAN, LK ;
HOPKINS, JB .
JOURNAL OF PHYSICAL CHEMISTRY, 1990, 94 (02) :729-736
[3]   LIGHT-SCATTERING FROM NONEQUILIBRIUM ELECTRON-HOLE PLASMA EXCITED BY PICOSECOND LASER-PULSES IN GAAS [J].
COLLINS, CL ;
YU, PY .
SOLID STATE COMMUNICATIONS, 1984, 51 (03) :123-126
[4]  
COOPEY M, 1980, NATURE, V284, P568
[5]  
DELHAYE M, 1975, LASERS PHYSICAL CHEM, P213
[6]  
DOIG SJ, 1991, J PHYS CHEM-US, V95, P6372, DOI 10.1021/j100169a054
[7]  
FLEMING GR, 1986, CHEM APPLICATIONS UL
[8]   PICOSECOND TRANSIENT RAMAN-SPECTROSCOPY - THE PHOTO-ISOMERIZATION OF TRANS-STILBENE [J].
GUSTAFSON, TL ;
ROBERTS, DM ;
CHERNOFF, DA .
JOURNAL OF CHEMICAL PHYSICS, 1983, 79 (04) :1559-1564
[9]   A CONVENIENT LINE-ELIMINATION OPTICAL FILTER FOR MULTICHANNEL RAMAN-SPECTROSCOPY [J].
HAMAGUCHI, H ;
KAMOGAWA, K .
APPLIED SPECTROSCOPY, 1986, 40 (04) :564-566