TOWARDS AN IDEAL BLOOD ANALOG FOR DOPPLER ULTRASOUND PHANTOMS

被引:50
作者
OATES, CP
机构
[1] Regional Med. Phys. Dept., District Gen. Hospital, Sunderland
关键词
D O I
10.1088/0031-9155/36/11/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
If a phantom is to produce Doppler spectral waveforms accurately matching those that would be obtained in vivo, it is necessary to use a fluid that behaves like blood in vivo, both acoustically and rheologically. The use of blood itself is undesirable and an analogue is required. Blood exhibits non-Newtonian behaviour as a result of aggregation of erythrocytes at low shear rates. This behaviour affects flow not only in sub-millimetre diameter vessels, but also in large scale structures. An alternative to blood is described that uses finely powdered nylon suspended in a mixture of glycerol and water. The nylon particles used have dimensions and density close to those of erythrocytes and they aggregate at low shear rates to give non-Newtonian behaviour. Viscosity may be varied over a wide range by the addition of liquid detergent. Consideration is given to the importance of haematocrit in modelling pulsatile and disturbed flows as it affects the haemodynamics of flow and the backscattered power of an ultrasound beam. This adaptable blood analogue is suitable for use in models of both large structures and fine vessels.
引用
收藏
页码:1433 / 1442
页数:10
相关论文
共 21 条
[1]   THEORETICAL-STUDY OF THE SCATTERING OF ULTRASOUND FROM BLOOD [J].
ANGELSEN, BAJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (02) :61-67
[2]   VELOCITY OF ULTRASOUND IN HUMAN BLOOD UNDER VARYING PHYSIOLOGIC PARAMETERS [J].
BRADLEY, EL ;
SACERIO, J .
JOURNAL OF SURGICAL RESEARCH, 1972, 12 (04) :290-&
[3]  
Diem K., 1970, DOCUMENTA GEIGY SCI
[4]  
Dintenfass L., 1985, BLOOD VISCOSITY
[5]   A LASER DOPPLER SCANNER FOR IMAGING BLOOD-FLOW IN SKIN [J].
ESSEX, TJH ;
BYRNE, PO .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (03) :189-194
[6]   The viscosity of the blood in narrow capillary tubes [J].
Fahraeus, R ;
Lindqvist, T .
AMERICAN JOURNAL OF PHYSIOLOGY, 1931, 96 (03) :562-568
[7]   A COMPARISON OF THE DOPPLER SPECTRA FROM HUMAN BLOOD AND ARTIFICIAL BLOOD USED IN A FLOW PHANTOM [J].
HOSKINS, PR ;
LOUPAS, T ;
MCDICKEN, WN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (02) :141-147
[8]   ON THE DESIGN AND EVALUATION OF A STEADY FLOW MODEL FOR DOPPLER ULTRASOUND STUDIES [J].
LAW, YF ;
JOHNSTON, KW ;
ROUTH, HF ;
COBBOLD, RSC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (05) :505-516
[9]  
LIEPSCH D, 1984, BIORHEOLOGY, V21, P571
[10]   AN EXPERIMENTAL-STUDY OF NEWTONIAN AND NON-NEWTONIAN FLOW DYNAMICS IN A VENTRICULAR ASSIST DEVICE [J].
MANN, KA ;
DEUTSCH, S ;
TARBELL, JM ;
GESELOWITZ, DB ;
ROSENBERG, G ;
PIERCE, WS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (02) :139-147