RAPID MEASUREMENTS OF DIASTOLIC INTRAMYOCARDIAL VASCULAR VOLUME

被引:20
作者
JUDD, RM
RESAR, JR
YIN, FCP
机构
[1] JOHNS HOPKINS MED INST, DEPT MED, BALTIMORE, MD 21205 USA
[2] JOHNS HOPKINS MED INST, DEPT BIOMED ENGN, BALTIMORE, MD 21205 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1993年 / 265卷 / 04期
关键词
CORONARY CAPACITANCE; CORONARY BLOOD VOLUME; DIASTOLE; CONTRAST AGENTS; DIGITAL SUBTRACTION ANGIOGRAPHY;
D O I
10.1152/ajpheart.1993.265.4.H1038
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Rapid measurements of coronary vascular volume are necessary for a complete understanding of phasic coronary flow. Because no standard method is capable of making these measurements, we developed a method that uses digital subtraction angiography to image an intravascular contrast agent. The method is capable of measuring vascular volume in 33 ms and can be repeated three times per second. The method was first validated in phantoms. We then used this method to measure coronary vascular volume in the isolated, perfluoro-chemical-perfused, interventricular canine septum. The speed of the measurements allowed us, for the first time, to directly measure transients in vascular volume following sudden changes in perfusion pressure. At the steady-state and maximal vasodilation, coronary vascular volume varied from 7.5 +/- 1.2 (SE) ml/100 g at a perfusion pressure of 20 mmHg to 12.1 +/- 1.9 ml/100 g at 90 mmHg, which is similar to other reports. After a sudden change of 40 mmHg in perfusion pressure, vascular volume changed with a time constant of 3.2 +/- 0.3 (SE) s. Increasing ventricular wall stretch had no effect on either the steady-state volumes (P = 0.25) or the time constant for volume changes (P = 0.17). The fact that the time constant is longer than the cardiac cycle, yet much shorter than the time necessary to measure vascular volume using other methods, highlights the need for rapid measurements of vascular volume.
引用
收藏
页码:H1038 / H1047
页数:10
相关论文
共 32 条
[1]  
BASSINGTHWAIGHT.JB, 1984, HDB PHYSL 2, V4, P549
[2]   PHASIC VOLUMETRIC CORONARY VENOUS OUTFLOW PATTERNS IN CONSCIOUS DOGS [J].
CANTY, JM ;
BROOKS, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (05) :H1457-H1463
[3]   1ST-PASS ENTRY OF NONIONIC CONTRAST AGENT INTO THE MYOCARDIAL EXTRAVASCULAR SPACE - EFFECTS ON RADIOGRAPHIC ESTIMATES OF TRANSIT-TIME AND BLOOD-VOLUME [J].
CANTY, JM ;
JUDD, RM ;
BRODY, AS ;
KLOCKE, FJ .
CIRCULATION, 1991, 84 (05) :2071-2078
[4]   RADIOGRAPHIC BLOOD POOL CONTRAST AGENTS FOR VASCULAR AND TUMOR IMAGING WITH PROJECTION RADIOGRAPHY AND COMPUTED-TOMOGRAPHY [J].
CASSEL, DM ;
YOUNG, SW ;
BRODY, WR ;
MULLER, HH ;
HALL, AL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (01) :141-146
[5]  
CHIEN S, 1984, HDB PHYSL 2, V4, P217
[6]   INFLUENCE OF CORONARY PERFUSION AND MYOCARDIAL EDEMA ON PRESSURE-VOLUME DIAGRAM OF LEFT VENTRICLE [J].
CROSS, CE ;
RIEBEN, PA ;
SALISBURY, PF .
AMERICAN JOURNAL OF PHYSIOLOGY, 1961, 201 (01) :102-&
[7]   SMALL VESSEL AND TOTAL CORONARY BLOOD-VOLUME DURING INTRA-CORONARY ADENOSINE [J].
CRYSTAL, GJ ;
DOWNEY, HF ;
BASHOUR, FA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (02) :H194-H201
[8]   DIGITAL ANGIOGRAPHIC IMPULSE-RESPONSE ANALYSIS OF REGIONAL MYOCARDIAL PERFUSION - LINEARITY, REPRODUCIBILITY, ACCURACY, AND COMPARISON WITH CONVENTIONAL INDICATOR DILUTION CURVE PARAMETERS IN PHANTOM AND CANINE MODELS [J].
EIGLER, NL ;
PFAFF, JM ;
ZEIHER, A ;
WHITING, JS ;
FORRESTER, JS .
CIRCULATION RESEARCH, 1989, 64 (05) :853-866
[9]  
GAEHTGENS P, 1980, BIORHEOLOGY, V17, P183
[10]   MORPHOMETRIC STUDY OF ENDOMYOCARDIUM AND EPIMYOCARDIUM OF THE LEFT-VENTRICLE IN ADULT DOGS [J].
GERDES, AM ;
KASTEN, FH .
AMERICAN JOURNAL OF ANATOMY, 1980, 159 (04) :389-394