MEASUREMENTS OF THE SIZE DISTRIBUTION OF AEROSOLS PRODUCED BY ULTRASONIC HUMIDIFICATION

被引:60
作者
RODES, C
SMITH, T
CROUSE, R
RAMACHANDRAN, G
机构
[1] Department of Environmental Sciences and Engineering, School of Public Health, University of North Carolina, Chapel Hill, NC
关键词
D O I
10.1080/02786829008959440
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Aerosol number and mass distributions produced by an ultrasonic room humidifier and an ultrasonic medical nebulizer were examined in a limited-scale study. Rapid droplet drying occurred at room humidities and under near saturated conditions. A model was tested describing the diameter of dried particles as a function of the dissolved mineral content of the water and the transducer frequency. Water containing 102 mg/L of dissolved minerals in a humidifier with a 1.6 MHz transducer produced droplets with a mass median diameter of 2.9 μm. The number median diameter of particles after drying was computed to be 0.11 μm. The distribution of particles in a nebulizer tube using a NaCl solution was shown to consist of a mixture of dried salt particles and droplets which included coagulated multiplets. © 1990 Elsevier Science Publishing Co., Inc.
引用
收藏
页码:220 / 229
页数:10
相关论文
共 17 条