CHARACTERIZATION OF INVIVO STRAIN IN THE RAT TIBIA DURING EXTERNAL APPLICATION OF A 4-POINT BENDING LOAD

被引:74
作者
AKHTER, MP [1 ]
RAAB, DM [1 ]
TURNER, CH [1 ]
KIMMEL, DB [1 ]
RECKER, RR [1 ]
机构
[1] INDIANA UNIV,BIOMECH & BIOMAT RES CTR,INDIANAPOLIS,IN 46202
关键词
D O I
10.1016/0021-9290(92)90082-C
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes a technique for characterizing strains and stresses induced in vivo in the rat tibia during application of an external four-point bending load. An external load was applied through the muscle and soft tissue with a four-point bending device, to induce strain in a 11 mm section of the right tibiae of ten adult female Sprague-Dawley rats. Induced strains were measured in vivo on the lateral surface of the tibia. Inter-rat difference, leg positioning and strain gage placement were evaluated as sources of variability of applied strains. Beam bending theory was used to predict externally induced in vivo strains. Finite element analysis was used to quantify the magnitude of shear stresses induced by this type of loading. There was a linear relationship between applied load and induced in vivo strains. In vivo strains induced by external loading were linearly correlated (R2 = 0.87) with the strains calculated using beam bending theory. The finite clement analysis predicted shear stresses at less than 10% of the longitudinal stresses resulting from four-point bending. Strains predicted along the tibia by finite element analysis and beam bending theory were well-correlated. Inter-rat variability due to tibial size and shape difference was the most important source of variation in induced strain (CV = 21.6%). Leg positioning was less important (CV = 9.5%).
引用
收藏
页码:1241 / 1246
页数:6
相关论文
共 19 条
[1]   THE EFFECTS OF ALTERED STRAIN ENVIRONMENTS ON BONE TISSUE KINETICS [J].
BURR, DB ;
SCHAFFLER, MB ;
YANG, KH ;
WU, DD ;
LUKOSCHEK, M ;
KANDZARI, D ;
SIVANERI, N ;
BLAHA, JD ;
RADIN, EL .
BONE, 1989, 10 (03) :215-221
[2]   AGING OF BONE TISSUE - MECHANICAL-PROPERTIES [J].
BURSTEIN, AH ;
REILLY, DT ;
MARTENS, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) :82-86
[3]  
CHURCHES AE, 1982, CLIN ORTHOP RELAT R, V168, P265
[4]   IMPLANTATION OF STRAIN GAGES ON BONE IN-VIVO [J].
COCHRAN, GVB .
JOURNAL OF BIOMECHANICS, 1972, 5 (01) :119-&
[5]  
GIES AA, 1982, J BIOMECH, V22, P297
[6]   FUNCTIONAL ADAPTATION OF BONE TO INCREASED STRESS - EXPERIMENTAL-STUDY [J].
GOODSHIP, AE ;
LANYON, LE ;
MCFIE, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (04) :539-546
[7]   EFFECT OF (ASU1,7)-EEL CALCITONIN ON THE PREVENTION OF OSTEOPOROSIS INDUCED BY COMBINATION OF IMMOBILIZATION AND OVARIECTOMY IN THE RAT [J].
HAYASHI, T ;
YAMAMURO, T ;
OKUMURA, H ;
KASAI, R ;
TADA, K .
BONE, 1989, 10 (01) :25-28
[8]   HUMAN PARATHYROID HORMONE-(1-34) INCREASES BONE MASS IN OVARIECTOMIZED AND ORCHIDECTOMIZED RATS [J].
HOCK, JM ;
GERA, I ;
FONSECA, J ;
RAISZ, LG .
ENDOCRINOLOGY, 1988, 122 (06) :2899-2904
[9]   REGULATION OF BONE STRESS AND STRAIN IN THE IMMATURE AND MATURE RAT FEMUR [J].
KELLER, TS ;
SPENGLER, DM .
JOURNAL OF BIOMECHANICS, 1989, 22 (11-12) :1115-1127
[10]   INVIVO STRAIN-GAUGE IMPLANTATION IN RATS [J].
KELLER, TS ;
SPENGLER, DM .
JOURNAL OF BIOMECHANICS, 1982, 15 (12) :911-917