THE USE OF TL-201 IN THE PREOPERATIVE DETECTION OF BREAST-CANCER - AN ADJUNCT TO MAMMOGRAPHY AND ULTRASONOGRAPHY

被引:33
作者
CIMITAN, M
VOLPE, R
CANDIANI, E
GUSSO, G
RUFFO, R
BORSATTI, E
MASSARUT, S
ROSSI, C
MORASSUT, S
CARBONE, A
机构
[1] IRCCS,CTR RIFERIMENTO ONCOL,DIV PATHOL,AVIANO,ITALY
[2] IRCCS,CTR RIFERIMENTO ONCOL,DIV SURG ONCOL,AVIANO,ITALY
[3] IRCCS,CTR RIFERIMENTO ONCOL,DEPT RADIOL,AVIANO,ITALY
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1995年 / 22卷 / 10期
关键词
TL-201; BREAST CANCER; PATHOLOGICAL FEATURES; RADIONUCLIDE IMAGING;
D O I
10.1007/BF00800591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Thallium-201 breast scans were performed preoperatively in 72 female patients with breast abnormalities detected by mammography and/or ultrasonography (7.5-13 MHz), in order to differentiate benign from malignant breast disease. informed consent was obtained from each patient. Scintigraphy consisted of anterior and oblique planar images of the affected breast and axilla at 10 min and 3 h following the injection of (TI)-T-201 chloride (110 MBq). All (TI)-T-201 scans were interpreted without prior knowledge of surgery data. Pathological features of breast malignancies, such as tumour size, axillary lymph node metastases, tumour grading, lymphatic vascular channel invasion and receptor status, were analysed for their association with (TI)-T-201 uptake by tumour cells. A total of 76 breast lesions were assessed in the study. On final histological diagnosis, there were 56 malignant tumours, 14 benign nodules (9 fibroadenomas, two cases of adenosis, two cases of focal fibrosis and one case of epitheliosis) and six atypical lesions (atypical ductal or lobular hyperplasia). Thallium scintigraphy was shown to have high accuracy (92%) in detecting breast cancer, better than mammography (74%) and ultrasonography (84%). Almost all (51/56) breast cancers showed greater (TI)-T-201 activity than surrounding normal breast tissue while there was no significant increase in (TI)-T-201 activity above background in all but one (19/20) case of non-malignant disease. (TI)-T-201 activity within breast tumours, calculated as tumour/background (T/B) ratio, ranged between 1.2 and 2.5 with a mean value of 1.45. In our experience the concentration of thallium in the breast cancer seems to be primarily dependent on vascularity and tumour size rather than tumour grading, lymphatic/vascular invasion or receptor status. (TI)-T-201 scan sensitivity was 97% for malignant lesions larger than 1.5 cm (n=35) and 80% for lesions of 1.5 cm or less (n=21); however, five of the eight breast cancers smaller than 1.0 cm were also detectable by (TI)-T-201 scintigraphy, compared with five out of seven by mammography. Thallium scintigraphy would not be useful in evaluating the axilla for lymph node metastases (sensitivity 27%, specificity 77%).
引用
收藏
页码:1110 / 1117
页数:8
相关论文
共 33 条
[1]   BIODISTRIBUTIONS OF TL-201 IN TUMOR-BEARING ANIMALS AND INFLAMMATORY LESION INDUCED ANIMALS [J].
ANDO, A ;
ANDO, I ;
KATAYAMA, M ;
SANADA, S ;
HIRAKI, T ;
MORI, H ;
TONAMI, N ;
HISADA, K .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1987, 12 (11) :567-572
[2]   USE OF RADIOACTIVE POTASSIUM (K-42) IN THE STUDY OF BENIGN AND MALIGNANT BREAST TUMORS [J].
BAKER, WH ;
NATHANSON, IT ;
SELVERSTONE, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1955, 252 (15) :612-615
[3]   BREAST SONOGRAPHY [J].
BASSETT, LW ;
KIMMESMITH, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (03) :449-455
[4]  
BURAK Z, 1994, EUR J NUCL MED, V21, pS113
[5]   A PROSPECTIVE-STUDY OF THE DEVELOPMENT OF BREAST-CANCER IN 16,692 WOMEN WITH BENIGN BREAST DISEASE [J].
CARTER, CL ;
CORLE, DK ;
MICOZZI, MS ;
SCHATZKIN, A ;
TAYLOR, PR .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1988, 128 (03) :467-477
[6]  
DEMONCEAU G, 1994, EUR J NUCL MED, V21, pS187
[7]  
Diggles L., 1994, Journal of Nuclear Medicine Technology, V22, P165
[8]   TL-201 AS A TUMOR-LOCALIZING AGENT - CURRENT STATUS AND FUTURE CONSIDERATIONS [J].
ELGAZZAR, AH ;
FERNANDEZULLOA, M ;
SILBERSTEIN, EB .
NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (02) :96-103
[9]   NONPALPABLE BREAST-LESIONS - RECOMMENDATIONS FOR BIOPSY BASED ON SUSPICION OF CARCINOMA AT MAMMOGRAPHY [J].
HALL, FM ;
STORELLA, JM ;
SILVERSTONE, DZ ;
WYSHAK, G .
RADIOLOGY, 1988, 167 (02) :353-358
[10]   NONPALPABLE BREAST-LESIONS - ACCURACY OF PREBIOPSY MAMMOGRAPHIC DIAGNOSIS [J].
HERMANN, G ;
JANUS, C ;
SCHWARTZ, IS ;
KRIVISKY, B ;
BIER, S ;
RABINOWITZ, JG .
RADIOLOGY, 1987, 165 (02) :323-326