SIMULTANEOUS DUAL-COLUMN, DUAL-DETECTOR GAS-CHROMATOGRAPHIC DETERMINATION OF CHLORINATED PESTICIDES AND POLYCHLORINATED-BIPHENYLS IN ENVIRONMENTAL-SAMPLES

被引:24
作者
DURELL, GS [1 ]
SAUER, TC [1 ]
机构
[1] ARTHUR D LITTLE INC,MARINE SCI UNIT,CAMBRIDGE,MA 02140
关键词
D O I
10.1021/ac00216a025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The lack of confirmation of Identified analytes In environmental gas chromatography (GC) that uses the traditional one-column, one-detector systems (e.g., GC-electron capture detection with a nonpolar column) often raises questions as to the validity of the data. To avoid misidentification of chlorinated pesticides and polychlorinated biphenyls (PCB), we conducted simultaneous dual-column, dual-detector GC analysis. Within one GC instrument, injected sample extracts were spilt In two and each portion passed through a capillary column of different polarity. A traditional nonpolar column, DB-5, was connected to an electron capture detector for initial identification of analytes; a more polar column, DB-17, was used with the halogen-specific electrolytic conductivity detector for confirmation analysis. GC column retention characteristics were determined for a large set of environmentally important pesticides and PCB congeners for the DB-5 and DB-17 analytical columns. The dual-column, dual-detector system was then evaluated on a large number of environmental samples of different matrix types. Results indicated that a substantial number of analytes, especially pesticides, may be incorrectly identified In environmental samples with one-column, one-detector systems. Use of a simultaneous dual-column, dual-detector system, substantially decreases the risk of false-positive Identifications without significantly Increasing the cost or time of analysis. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:1867 / 1871
页数:5
相关论文
共 10 条
[1]   COMPARISON OF THE COMPOSITIONS OF AROCLOR-1242 AND AROCLOR-1016 [J].
ALBRO, PW ;
PARKER, CE .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :161-166
[2]   QUANTITATIVE CHARACTERIZATION OF POLYCHLORINATED BIPHENYL MIXTURES (AROCLOR-1248, AROCLOR-1254 AND AROCLOR-1260) BY GAS-CHROMATOGRAPHY USING CAPILLARY COLUMNS [J].
ALBRO, PW ;
CORBETT, JT ;
SCHROEDER, JL .
JOURNAL OF CHROMATOGRAPHY, 1981, 205 (01) :103-111
[3]   ANALYZING PCBS [J].
ALFORDSTEVENS, AL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (12) :1194-1199
[4]  
CAIRNS T, 1981, ANAL CHEM, V53, P1183
[5]   DETERMINATION OF POLYCHLORINATED-BIPHENYLS IN TRANSFORMER OILS BY CAPILLARY GAS-CHROMATOGRAPHY [J].
GORDON, RJ ;
SZITA, J ;
FAEDER, EJ .
ANALYTICAL CHEMISTRY, 1982, 54 (03) :478-481
[6]   CONCENTRATIONS OF CHLORINATED PESTICIDES AND PCBS IN MICROLAYER AND SEAWATER SAMPLES COLLECTED IN OPEN-OCEAN WATERS OFF THE UNITED-STATES EAST COAST AND IN THE GULF OF MEXICO [J].
SAUER, TC ;
DURELL, GS ;
BROWN, JS ;
REDFORD, D ;
BOEHM, PD .
MARINE CHEMISTRY, 1989, 27 (3-4) :235-257
[7]  
SAUER TC, 1988, UNPUB ANAL RESULTS S
[8]   PARALLEL CAPILLARY COLUMN GAS-CHROMATOGRAPHY IN THE DETERMINATION OF CHLORINATED PESTICIDES AND PCBS [J].
SCHNEIDER, JF ;
BOURNE, S ;
BOPARAI, AS .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (05) :203-206
[9]   EVALUATION OF SAMPLE PREPARATION TECHNIQUES FOR THE ANALYSIS OF PCBS IN OIL [J].
SONCHIK, S ;
MADELEINE, D ;
MACEK, P ;
LONGBOTTOM, J .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1984, 22 (07) :265-271
[10]  
1979, MANUAL ANAL QUALITY