MEASUREMENT OF INSPIRATORY MUSCLE PERFORMANCE WITH INCREMENTAL THRESHOLD LOADING - A COMPARISON OF 2 TECHNIQUES

被引:13
作者
BARDSLEY, PA [1 ]
BENTLEY, S [1 ]
HALL, HS [1 ]
SINGH, SJ [1 ]
EVANS, DH [1 ]
MORGAN, MDL [1 ]
机构
[1] UNIV LEICESTER,DEPT MED PHYS,LEICESTER LE1 7RH,ENGLAND
关键词
D O I
10.1136/thx.48.4.354
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background-Incremental threshold loading (ITL) is a test of inspiratory muscle performance which is usually performed by breathing through a weighted inspiratory plunger, the load on the inspiratory muscles being increased by externally adding weights to the intake valve. This is not a true threshold device and may be inaccurate. This method was compared with a true threshold device consisting of a solenoid valve which only opens to supply air at a predetermined negative mouth pressure. Methods-Six naive, normal subjects (three men and three women) aged 22-24 years underwent three tests using each system. The inspiratory loads were increased every minute by equivalent amounts, -10 cm H2O with the solenoid valve and by 50 g with the weighted plunger, until the subjects could not inspire or sustain inspiration for a full minute. Six experienced subjects (four men and two women) aged 23-41 years were subsequently randomised to perform ITL with the solenoid valve, twice with the breathing pattern fixed and twice free. Results-The solenoid valve generated a more accurate mouth pressure response and was less variable at higher loads than the weighted plunger. The work performed (expressed as the pressure-time product) was less with the solenoid valve but was more reproducible. ITL with the solenoid valve was not influenced by controlling the breathing pattern of the subjects. Conclusions-The solenoid valve has several features that make it superior to the weighted plunger as a device for ITL. It generates a more accurate mouth pressure response which is less variable at higher loads. Increases in load are smoother and quicker to introduce. ITL with the solenoid valve is not influenced by varying breathing patterns and does not require any external regulation.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 10 条
[1]  
BLACK LF, 1971, AM REV RESPIR DIS, V103, P641
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   EFFECTS OF BREATHING PATTERN ON INSPIRATORY MUSCLE ENDURANCE IN HUMANS [J].
CLANTON, TL ;
DIXON, GF ;
DRAKE, J ;
GADEK, JE .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (06) :1834-1841
[4]   PRESSURE-TIME PRODUCT, FLOW, AND OXYGEN COST OF RESISTIVE BREATHING IN HUMANS [J].
COLLETT, PW ;
PERRY, C ;
ENGEL, LA .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (04) :1263-1272
[5]   SUSTAINED MAXIMUM VOLUNTARY VENTILATION [J].
FREEDMAN, S .
RESPIRATION PHYSIOLOGY, 1970, 8 (02) :230-&
[6]   MEASUREMENT OF INSPIRATORY MUSCLE PERFORMANCE WITH INCREMENTAL THRESHOLD LOADING [J].
MARTYN, JB ;
MORENO, RH ;
PARE, PD ;
PARDY, RL .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 135 (04) :919-923
[7]   COMPARISON OF 2-MINUTE INCREMENTAL THRESHOLD LOADING AND MAXIMAL LOADING AS MEASURES OF RESPIRATORY MUSCLE ENDURANCE [J].
MCELVANEY, G ;
FAIRBARN, MS ;
WILCOX, PG ;
PARDY, RL .
CHEST, 1989, 96 (03) :557-563
[8]   MEASURING VENTILATORY MUSCLE ENDURANCE IN HUMANS AS SUSTAINABLE INSPIRATORY PRESSURE [J].
NICKERSON, BG ;
KEENS, TG .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (03) :768-772
[9]   FATIGUE OF INSPIRATORY MUSCLES AND THEIR SYNERGIC BEHAVIOR [J].
ROUSSOS, C ;
FIXLEY, M ;
GROSS, D ;
MACKLEM, PT .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (05) :897-904
[10]   DIAPHRAGMATIC FATIGUE IN MAN [J].
ROUSSOS, CS ;
MACKLEM, PT .
JOURNAL OF APPLIED PHYSIOLOGY, 1977, 43 (02) :189-197