ANATOMIC COMPARISON OF THE ROY-CAMILLE AND MAGERL TECHNIQUES FOR SCREW PLACEMENT IN THE LOWER CERVICAL-SPINE

被引:91
作者
HELLER, JG
CARLSON, GD
ABITBOL, JJ
GARFIN, SR
机构
[1] Department of Orthopaedic Surgery, Emory University, School of Medicine, Atlanta, GA
[2] Division of Orthopaedics and Rehabilitation, University of California, San Diego, CA
关键词
CERVICAL SPINE; INTERNAL FIXATION; SCREW PLACEMENT; ANATOMIC RISKS;
D O I
10.1097/00007632-199110001-00020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The Roy-Camille and Magerl techniques for screw placement in the lower cervical spine were compared under simulated operating room conditions. Three surgeons with varying years of spine surgery experience participated. The anatomic morbidity risks of each screw insertion technique were evaluated by anatomic dissection and radiographic examination. The spinal cord and vertebral arteries were not threatened by either method. Analysis of the pooled data revealed that the Roy-Camille technique had less risk of nerve root injury, nerve roots placed "at risk" for injury, and errors in "zone" of placement. The Magerl technique had less risk of facet joint violation. A learning curve was observed. Once the surgeons gained experience with the two techniques, there were no longer any statistically significant differences among them. The number of years of spine surgery practice did not influence the morbidity risk of either technique. The surgeons' ability to aim the screws was identical in the axial plane, but consistently less accurate in the sagittal plane for the Magerl screws because of the normal prominence of the cervicothoracic junction. Thorough familiarity with the regional anatomy and practice in the anatomy laboratory are recommended before performing these techniques in patients.
引用
收藏
页码:S552 / S557
页数:6
相关论文
共 11 条
[1]  
Gill K., Paschal S., Corin J., Ashman R., Bucholz R.W., Posterior plating of the cervical spine: A biomechanical comparison of different posterior fusion techniques, Spine, 13, pp. 813-816, (1988)
[2]  
Grady S.M., Erson P.A., Henley M.B., Posterior Cervical Fusion Using AO Reconstruction Plates and Iliac Bone Graft [Abstract], (1990)
[3]  
Holness R.O., Huestis W.S., Howes W.J., Langille R.A., Posterior stabilization with an interlaminar clamp in cervical injuries: Technical notes and review of long term experience with the method, Neurosurgery, 14, pp. 318-322, (1984)
[4]  
Magerl F., (1988)
[5]  
McAfee P.C., Bohlman H.H., Wilson W.L., The triple wire fixation technique for stabilization of acute fracture-dislocations: A biomechanical analysis, Orthop Trans, 9, (1985)
[6]  
Robinson R.A., Southwick W.O., Indications and techniques for early stabilization of the neck in some fracture dislocations of the cervical spine, South Med J, 53, (1960)
[7]  
Rogers W.A., Treatment of fracture-dislocation of the cervical spine, J Bone Joint Surg, 24A, pp. 245-258, (1942)
[8]  
Roy-Camille R., Methods of Osteosynthesis with Posterior Screw Plates in Atlas of Orthopaedic Surgery, 1, pp. 373-376, (1989)
[9]  
Sutterlin I., McAfee P.C., Warden K.E., Rey R.M., Farey I.D., A biomechanical evaluation of cervical spinal stabilization methods in a bovine model: Static and cyclical loading, Spine, 13, pp. 795-802, (1988)
[10]  
Ulrich C., Worsdorfer O., Claes L., Magerl F., Comparative study of the stability of anterior and posterior cervical spine fixation procedures, Arch Orthop Trauma Surg, 106, pp. 226-2331, (1987)