COMPARATIVE REPRODUCIBILITY OF PROXIMAL PROBING DEPTH USING ELECTRONIC PRESSURE-CONTROLLED AND HAND PROBING

被引:16
作者
MULLALLY, BH
LINDEN, GJ
机构
[1] Department of Restorative Dentistry, School of Clinical Dentistry, Queens University, Belfast, BT12 6BP, Grosvenor Road
关键词
ELECTRONIC PRESSURE; SENSITIVE PROBE; PROBING DEPTH; REPRODUCIBILITY;
D O I
10.1111/j.1600-051X.1994.tb00319.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This investigation assessed the effect of an electronic pressure-sensitive probe on the reproducibility of probing-depth measurement. Clinical measurements were made at the mesial and distal aspects of all teeth from the buccal and palatal or lingual aspects. Probing was carried out either in a conventional manner using gentle pressure referred to as hand probing or using an electronic pressure-sensitive probe set at 25 g and referred to as pressure-controlled probing. Probing-depth recordings were repeated for one randomly selected quadrant in each subject with random application of the 4 different combinations of pressure-controlled and hand probing. A total of 2584 replicate pairs of probing depth measurements were recorded on 4 proximal surfaces in 646 teeth in 100 adult subjects. The majority (98%) of all repeated measurements were within 1 mm of the initial values. The highest levels of agreement resulted when the same probing method was used at both examinations with electronic pressure-controlled probing being superior to hand probing regardless of tooth position or site. Duplicate measurements recorded with combinations of hand and pressure-controlled probing showed significant systematic bias towards shallower pocket depths with electronic pressure-controlled probing.
引用
收藏
页码:284 / 288
页数:5
相关论文
共 22 条
[1]   MEASURING AND INTERPRETING INCREASES IN PROBING DEPTH AND ATTACHMENT LOSS [J].
AEPPLI, DM ;
BOEN, JR ;
BANDT, CL .
JOURNAL OF PERIODONTOLOGY, 1985, 56 (05) :262-264
[2]   MICROSCOPIC EVALUATION OF CLINICAL MEASUREMENTS OF CONNECTIVE-TISSUE ATTACHMENT LEVELS [J].
ARMITAGE, GC ;
SVANBERG, GK ;
LOE, H .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1977, 4 (03) :173-190
[3]  
ATASSI F, 1992, J CLIN PERIODONTOL, V19, P301
[4]   REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS [J].
BADERSTEN, A ;
NILVEUS, R ;
EGELBERG, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) :475-485
[5]  
CATON J, 1982, J PERIODONTOL, V52, P626
[6]   EVALUATION OF PERIODONTAL PROBING FORCES [J].
FREED, HK ;
GAPPER, RL ;
KALKWARF, KL .
JOURNAL OF PERIODONTOLOGY, 1983, 54 (08) :488-492
[7]   DESCRIPTION AND CLINICAL-EVALUATION OF A NEW COMPUTERIZED PERIODONTAL PROBE - THE FLORIDA PROBE [J].
GIBBS, CH ;
HIRSCHFELD, JW ;
LEE, JG ;
LOW, SB ;
MAGNUSSON, I ;
THOUSAND, RR ;
YERNENI, P ;
CLARK, WB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (02) :137-144
[8]  
GLAVIND LEIF, 1967, J PERIODONTAL RES, V2, P180, DOI 10.1111/j.1600-0765.1967.tb01887.x
[9]   PATTERNS OF PROGRESSION AND REGRESSION OF ADVANCED DESTRUCTIVE PERIODONTAL-DISEASE [J].
GOODSON, JM ;
TANNER, ACR ;
HAFFAJEE, AD ;
SORNBERGER, GC ;
SOCRANSKY, SS .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1982, 9 (06) :472-481
[10]   A NEW PERIODONTAL PROBE WITH AUTOMATED CEMENTO-ENAMEL JUNCTION DETECTION [J].
JEFFCOAT, MK ;
JEFFCOAT, RL ;
JENS, SC ;
CAPTAIN, K .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1986, 13 (04) :276-280