SPECTRAL INTERPRETATION AND INTERFERENCE CORRECTION IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY

被引:34
作者
VANVEEN, EH
BOSCH, S
DELOOSVOLLEBREGT, MTC
机构
[1] Laboratory of Materials Science, Atomic Spectrometry Unit, Delft University of Technology, 2628 AL Delft
关键词
D O I
10.1016/0584-8547(94)80114-2
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
To tackle the several problematic polyatomic interferences in inductively coupled plasma mass spectrometry (ICP-MS), we have developed a software approach based on data reduction of the measured total mass spectrum through multicomponent analysis (MCA). The approach leans on a working knowledge of interferents that are likely to be encountered in a sample matrix, which composition is known by virtue of the total mass spectrum and knowledge of applied solvents. The full isotopic patterns for all elements and expected interferents are used in the modelling MCA matrix of 250 masses x 105 species at maximum. Polyatomic abundances are calculated by the software. Since all species are modelled fundamentally through their known natural abundances, the MCA matrix can be manipulated and reprocessed until interpretation of the mass spectrum and, hence, interference correction are optimal. The optimum is attained by use of the bar graph and calculation modes of the PC software and criteria for properly found isotopic patterns. With optimized models stored in the data base, the user may routinely process samples in one go, and operate the ICP-MS system in a true all-element mode. Use of elemental equations or measurement of large multivariate calibration sets and pure component solutions are superfluous. Data reduction is solely based on the information about the isotopic patterns, present in the measured mass spectrum itself. As a result, in the case of interferences, detection limits may be lowered by one to two orders of magnitude. The approach is illustrated with an industrial example of Hf determined in NdFeB, and with an environmental example. Here, a suite of elements over the 50-82 amu mass range has been determined in different salt matrices in groundwater.
引用
收藏
页码:1347 / 1361
页数:15
相关论文
共 19 条
[2]   MS INTERVIEW - AN ELEMENTAL MASS-SPECTROMETRY SPECTRAL INTERFERENCE DATA-BASE [J].
BURTON, LL ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (14) :E1621-E1627
[3]  
BURTON LL, 1993, SPECTROCHIM ACTA B, V48, pE1063
[4]  
DATE AR, 1989, APPLICATIONS INDUCTI, P242
[5]  
DENOYER ER, 1994, ATOM SPECTROSC, V15, P7
[6]   LASER SOLID SAMPLING FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DENOYER, ER ;
FREDEEN, KJ ;
HAGER, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :A445-&
[7]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[8]   MULTIVARIATE METHODS FOR INTERPRETATION OF EMISSION-SPECTRA FROM THE INDUCTIVELY COUPLED PLASMA [J].
IVALDI, JC ;
TRACY, D ;
BARNARD, TW ;
SLAVIN, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (12) :1361-1371
[9]   MULTIVARIATE CALIBRATION IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY .2. EFFECT OF CHANGES IN ABUNDANCES OF INTERFERING POLYATOMIC IONS [J].
KETTERER, ME ;
BIDDLE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1819-1823
[10]   MULTIVARIATE CALIBRATION IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
KETTERER, ME ;
RESCHL, JJ ;
PETERS, MJ .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2031-2040