RELIABILITY OF CYBEX-II ISOKINETIC EVALUATIONS OF TORQUE IN POSTPOLIOMYELITIS SYNDROME

被引:12
作者
KILFOIL, MR [1 ]
STPIERRE, DMM [1 ]
机构
[1] MCGILL UNIV,SCH PHYS & OCCUPAT THERAPY,3645 DRUMMOND ST,MONTREAL H3G 1Y5,PQ,CANADA
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1993年 / 74卷 / 07期
关键词
ISOKINETIC; POLIOMYELITIS; POSTPOLIOMYELITIS SYNDROME; RELIABILITY;
D O I
10.1016/0003-9993(93)90034-8
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The aim of this study was to ascertain the reliability of isokinetic strength measurements in a population of post-poliomyelitis subjects (PPS). Eight subjects (four males and females, mean age of 47.5 ± 10 and 56.8 ± 16 years, respectively) were evaluated, on a weekly basis for three weeks at approximately the same time of day. During each test session the knee flexors and extensors (bilaterally, where possible) were evaluated. Subjects became familiar with the equipment prior to recording three maximal contractions at the four test velocities (1.05, 2.09, 3.14, 4.18rads · s-1). A two-minute rest period was allowed between sets of contractions. The variables of peak torque, angle of peak torque, torque at specific joint angles (0.79 and 1.05rads), total contractile work, maximum power, and average power were measured on-line with the Cybex II a system using a commercially available software package. In both muscle groups, all the variables were significantly weaker on the most affected, but testable limb (p < 0.01) in subjects where both limbs could be tested (n = 5). Peak torque and total work of the quadriceps were observed to decrease with increasing velocity of movement. The effects of velocity were less apparent in the hamstrings. Average and maximum power developed by the knee extensors and flexors increased with increasing velocity of movement. Reliability of performance over three test sessions was confirmed by the intraclass correlation coefficient (ICC) values derived from the univariate ANOVAs calculated for each of the above variables (>0.80). Angle of peak torque, however, was not found to be a reliable measurement across the three test sessions. Although subjects in the present study were tested on three separate occasions, reliability of peak torque over two test sessions was also observed. However, peak torque of flexion was more reliable on Days 2 and 3. This was especially true for knee flexion at 2.09 and 3.14rads · sec-1. In conclusion, this study demonstrated that a Cybex II isokinetic device is a reliable means to evaluate strength in persons with PPS. © 1993.
引用
收藏
页码:730 / 735
页数:6
相关论文
共 44 条
[1]  
AGRE JC, 1990, ARCH PHYS MED REHAB, V71, P545
[2]   USING ISOKINETIC DYNAMOMETRY TO TEST AMBULATORY PATIENTS WITH MULTIPLE-SCLEROSIS [J].
ARMSTRONG, LE ;
WINANT, DM ;
SWASEY, PR ;
SEIDLE, ME ;
CARTER, AL ;
GEHLSEN, G .
PHYSICAL THERAPY, 1983, 63 (08) :1274-1279
[3]   HISTOPATHOLOGIC BASIS OF CLINICAL FINDINGS IN POLIOMYELITIS [J].
BODIAN, D .
AMERICAN JOURNAL OF MEDICINE, 1949, 6 (05) :563-578
[4]  
BRUNO RL, 1991, ORTHOPEDICS, V14, P1185
[5]  
BRUNO RL, 1991, ORTHOPEDICS, V14, P1269
[6]  
BURDETT R G, 1987, Journal of Orthopaedic and Sports Physical Therapy, V8, P484
[7]   POST-POLIOMYELITIS SEQUELAE IN THE ELDERLY [J].
CIOCON, JO ;
POTTER, JF .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1989, 37 (03) :256-258
[8]  
CODD MB, 1985, LATE EFFECTS POLIOMY
[9]   A LONG-TERM FOLLOW-UP-STUDY OF PATIENTS WITH POSTPOLIOMYELITIS NEUROMUSCULAR SYMPTOMS [J].
DALAKAS, MC ;
ELDER, G ;
HALLETT, M ;
RAVITS, J ;
BAKER, M ;
PAPADOPOULOS, N ;
ALBRECHT, P ;
SEVER, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1986, 314 (15) :959-963
[10]  
de Boer A, 1982, Eng Med, V11, P169, DOI 10.1243/EMED_JOUR_1982_011_047_02