VELOCITY AND TURBULENCE MEASUREMENTS PAST MITRAL-VALVE PROSTHESES IN A MODEL LEFT-VENTRICLE

被引:27
作者
SCHOEPHOERSTER, RT
CHANDRAN, KB
机构
[1] UNIV IOWA,DEPT BIOMED ENGN,IOWA CITY,IA 52242
[2] UNIV IOWA,DEPT MECH ENGN,IOWA CITY,IA 52242
关键词
D O I
10.1016/0021-9290(91)90288-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Thrombogenesis and hemolysis have both been linked to the flow dynamics past heart valve prostheses. To learn more about the particular flow dynamics past mitral valve prostheses in the left ventricle under controlled experimental conditions, an in vitro study was performed. The experimental methods included velocity and turbulent shear stress measurements past caged-ball, tilting disc, bileaflet, and polyurethane trileaflet mitral valves in an acrylic rigid model of the left ventricle using laser Doppler anemometry. The results indicate that all four prosthetic heart valves studied create at least mildly disturbed flow fields. The effect of the left ventricular geometry on the flow development is to produce a stabilizing vortex which engulfs the entire left ventricular cavity, depending on the orientation of the valve. The measured turbulent shear stress magnitudes for all four valves did not exceed the reported value for hemolytic damage. However, the measured turbulent shear stresses were near or exceeded the critical shear stress reported in the literature for platelet lysis, a known precursor to thrombus formation.
引用
收藏
页码:549 / 562
页数:14
相关论文
共 23 条
[1]  
ADDONIZIO VP, 1985, CARDIOL CLIN, V3, P431
[2]  
Baldwin J T, 1989, ASAIO Trans, V35, P429, DOI 10.1097/00002480-198907000-00083
[3]   PULSATILE FLOW PAST AORTIC-VALVE BIOPROSTHESES IN A MODEL HUMAN AORTA [J].
CHANDRAN, KB ;
CABELL, GN ;
KHALIGHI, B ;
CHEN, CJ .
JOURNAL OF BIOMECHANICS, 1984, 17 (08) :609-&
[4]   LASER ANEMOMETRY MEASUREMENTS OF PULSATILE FLOW PAST AORTIC-VALVE PROSTHESES [J].
CHANDRAN, KB ;
CABELL, GN ;
KHALIGHI, B ;
CHEN, CJ .
JOURNAL OF BIOMECHANICS, 1983, 16 (10) :865-873
[5]   INVITRO COMPARISON OF VELOCITY PROFILES AND TURBULENT SHEAR DISTAL TO POLYURETHANE TRILEAFLET AND PERICARDIAL PROSTHETIC VALVES [J].
CHANDRAN, KB ;
FATEMI, R ;
SCHOEPHOERSTER, R ;
WURZEL, D ;
HANSEN, G ;
PANTALOS, G ;
YU, LS ;
KOLFF, WJ .
ARTIFICIAL ORGANS, 1989, 13 (02) :148-154
[6]   EFFECT OF PROSTHETIC MITRAL-VALVE GEOMETRY AND ORIENTATION ON FLOW DYNAMICS IN A MODEL HUMAN LEFT-VENTRICLE [J].
CHANDRAN, KB ;
SCHOEPHOERSTER, R ;
DELLSPERGER, KC .
JOURNAL OF BIOMECHANICS, 1989, 22 (01) :51-&
[7]   RHEOLOGIC APPROACH TO THROMBOSIS + ATHEROSCLEROSIS [J].
DINTENFASS, L .
ANGIOLOGY, 1964, 15 (08) :333-&
[8]  
FATEMI R, 1989, THESIS U IOWA
[9]  
HUNG TC, 1976, T AM SOC ART INT ORG, V22, P285
[10]  
JONES M, 1986, ECHOCARDIOGR-J CARD, V3, P513