Bioelectrical impedance analysis: Clinical tool in assessing total body water and thoracic fluid

被引:6
作者
DeVries, PMJM [1 ]
Noordegraaf, AV [1 ]
VanderMeer, BJM [1 ]
Woltjer, HH [1 ]
DeVries, JPPM [1 ]
机构
[1] FREE UNIV AMSTERDAM HOSP,DEPT MED PHYS,AMSTERDAM,NETHERLANDS
关键词
impedance analysis; total body water; thoracic fluid; hemodialysis; cardiac surgery;
D O I
10.1177/039139889501801102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bioelectrical impedance analysis forms a non-invasive tool for detection of body fluids. Total body measurement gives total body wafer (TBW) and, in case of multifrequency analysis, of intra- and extracellular fluid volume. The thoracic approach measures thoracic fluid (TF). The set-up of both techniques is discussed. An overview is given of the clinical usefulness of the total body technique to monitor fluid changes and the process of refill during hemodialysis and to detect dry weight. The simultaneous measurement of TBW and TF was applied to obtain a more detailed picture of the body fluids. In a group of healty subjects the age dependency of both variables was shown. During hemodialyss TBW and TF showed a major and comparable decrease. Fluid retention during cardiac surgery led to a slightly more pronounced increase of TF than of TBW. The combination of both impedance techniques offers clinicians a means to monitor alterations in fluid status in patients in more detail.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 31 条
[1]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[2]  
de Vries P M, 1988, ASAIO Trans, V34, P623
[3]   SIMULTANEOUS DETERMINATION OF EXTRACELLULAR VOLUME AND BLOOD VOLUME WITH VOLEMETRON [J].
DEPLANQU.BA ;
GEYSKES, CG ;
VANDONGE.R ;
MEES, EJD .
CLINICA CHIMICA ACTA, 1965, 11 (03) :270-&
[4]  
DEURENBERG P, 1991, INT J OBESITY, V15, P17
[5]  
DEVRIES JPP, 1993, T AM SOC ART INT ORG, V39, P368
[6]   NONINVASIVE MONITORING OF BLOOD-VOLUME DURING HEMODIALYSIS - ITS RELATION WITH POST-DIALYTIC DRY-WEIGHT [J].
DEVRIES, JPPM ;
KOUW, PM ;
VANDERMEER, NJM ;
OLTHOF, CG ;
OE, LP ;
DONKER, AJM ;
DEVRIES, PMJM .
KIDNEY INTERNATIONAL, 1993, 44 (04) :851-854
[7]  
DEVRIES PMJ, 1994, AGE NUTR, V5, P118
[8]   FLUID BALANCE DURING HEMODIALYSIS AND HEMOFILTRATION - THE EFFECT OF DIALYSATE SODIUM AND A VARIABLE ULTRAFILTRATION RATE [J].
DEVRIES, PMJM ;
OLTHOF, CG ;
SOLF, A ;
SCHUENEMANN, B ;
OE, PL ;
QUELLHORST, E ;
SCHNEIDER, H ;
DONKER, AJM .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 (04) :257-263
[9]   MEASUREMENT OF TRANS-CELLULAR FLUID SHIFT DURING HEMODIALYSIS .2. INVITRO AND CLINICAL-EVALUATION [J].
DEVRIES, PMJM ;
MEIJER, JH ;
VLAANDEREN, K ;
VISSER, V ;
OE, PL ;
DONKER, AJM ;
SCHNEIDER, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (02) :152-158
[10]   MICROPROCESSOR-BASED SYSTEM FOR MEASUREMENT OF ELECTRICAL IMPEDANCES DURING HEMODIALYSIS AND IN POSTOPERATIVE CARE [J].
GOOVAERTS, HG ;
DEVRIES, FR ;
MEIJER, JH ;
DEVRIES, PMJM ;
DONKER, AJM ;
SCHNEIDER, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (01) :75-80