DETERMINATION OF TRACE-ELEMENTS IN ANALYTICAL-REAGENT GRADE SODIUM-SALTS BY ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY AFTER PRECONCENTRATION BY COLUMN SOLID-PHASE EXTRACTION

被引:47
作者
ALEXANDROVA, A [1 ]
ARPADJAN, S [1 ]
机构
[1] UNIV SOFIA,FAC CHEM,BU-1126 SOFIA,BULGARIA
关键词
SOLID-PHASE EXTRACTION; SODIUM SALTS; ATOMIC ABSORPTION SPECTROMETRY; INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY;
D O I
10.1039/an9931801309
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Column solid phase extraction using solid ammonium hexahydroazepine-1-dithiocarboxylate (ammonium hexamethylenedithiocarbamate) (HMDC) mixed with polyurethane foam was applied to the preconcentration of trace amounts of Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni and Pd from analytical-reagent grade sodium salts prior to their measurements by atomic absorption spectrometry (AAS) or inductively coupled plasma atomic emission spectrometry (ICP-AES). A 2 ml disposable syringe served as a preconcentration column. Except for Cr, recoveries of sorption of the elements tested were higher than 98% with absolute blanks ranging between 5 ng (Co) and 50 ng (Cu). For AAS determination of the preconcentrated analytes, the solid chelate forming sorbent (HMDC) was completely dissolved in isobutyl methyl ketone (IBMK). Electrothermal AAS allows the determination of 1 x 10(-7)% Cd, 3 x 10(-7)% Mn, 5 x 10(-7)% Pb, 1 x 10(-6)% Co, 2 x 10(-6)% Ni, 4 x 10(-6)% Fe and 1 x 10(-5)% Cu. For ICP-AES measurements a quantitative elution was obtained with 4 mol l-1 HNO3 permitting the determination of 5 x 10(-6)% Cd and Mn, 1 x 10(-5)% Cu and Fe, 2 x 10(-5)% Ni and 1 x 10(-4)% Pb. The elution of Co and Hg from the sorbent with 4 mol l-1 HNO3 was incomplete.
引用
收藏
页码:1309 / 1312
页数:4
相关论文
共 23 条
[1]   EXTRACTION FLAME ATOMIC-ABSORPTION DETERMINATION OF MICROTRACES IN SALTS [J].
ARPADJAN, S ;
KARADJOVA, I ;
ALEXANDROV, S ;
TSALEV, D .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (06) :581-583
[2]  
ARPADJAN S, 1985, FRESEN Z ANAL CHEM, V321, P596
[3]  
BARNES RM, 1983, CAN J SPECTROSC, V28, P139
[4]   TRENDS IN USING RESILIENT POLYURETHANE FOAMS AS SORBENTS IN ANALYTICAL-CHEMISTRY [J].
BRAUN, T .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 314 (07) :652-656
[5]   ANALYTICAL MULTIELEMENT PRECONCENTRATION ON METAL HYDROXIDE-COATED CELLULOSE [J].
BURBA, P ;
WILLMER, PG .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 321 (02) :109-118
[6]   MULTIELEMENT-PRECONCENTRATION FOR ATOMIC SPECTROSCOPY BY SORPTION OF DITHIOCARBAMATE-METAL COMPLEXES (EG, HMDC) ON CELLULOSE COLLECTORS [J].
BURBA, P ;
WILLMER, PG .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 329 (05) :539-545
[7]   ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE-ELEMENTS BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CAROLI, S ;
ALIMONTI, A ;
PETRUCCI, F ;
HORVATH, Z .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :241-249
[8]  
GREENFIELD S, 1976, ICP INFORM NEWSL, V2, P167
[9]  
JONES JS, 1983, ATOM SPECTROSC, V4, P49
[10]  
KRASILCHIK VZ, 1988, VYSOKOCHISTYE VECHES, V3, P137