LOCALIZED T(1) MEASUREMENTS USING AN INVERSION-RECOVERY OSIRIS METHOD

被引:4
作者
GIRARD, F
POULET, P
STEIBEL, J
CHAMBRON, J
机构
[1] FAC MED STRASBOURG,INST PHYS BIOL,CNRS,URA 1173,F-67085 STRASBOURG,FRANCE
[2] FDN RECH NEUROSCI APPL PSYCHIAT,F-68250 ROUFFACH,FRANCE
关键词
D O I
10.1002/nbm.1940060603
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This work presents a new method for localized T1 measurements, based upon the OSIRIS scheme. It relies on the use of a non-selective 180-degrees pulse applied before the OSIRIS preparation cycle. The accuracy of the method has been verified with test tubes and in vivo for two nuclei, H-1 and F-19. The accuracy of the T1 values is discussed, as well as possible applications of the inversion-recovery method to non-invasive in vivo pO2 measurements.
引用
收藏
页码:366 / 370
页数:5
相关论文
共 19 条
[1]   INVIVO DETERMINATION OF MULTIEXPONENTIAL T2 RELAXATION IN THE BRAIN OF PATIENTS WITH MULTIPLE-SCLEROSIS [J].
ARMSPACH, JP ;
GOUNOT, D ;
RUMBACH, L ;
CHAMBRON, J .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :107-113
[2]   QUANTITATIVE-DETERMINATION OF THE PARTIAL OXYGEN-PRESSURE IN THE VITRECTOMIZED RABBIT EYE INVIVO USING F-19 NMR [J].
BERKOWITZ, BA ;
WILSON, CA ;
HATCHELL, DL ;
LONDON, RE .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) :233-241
[3]   FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE [J].
BRIX, G ;
SCHAD, LR ;
DEIMLING, M ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :351-356
[4]   OUTER VOLUME SUPPRESSED IMAGE RELATED INVIVO SPECTROSCOPY (OSIRIS), A HIGH-SENSITIVITY LOCALIZATION TECHNIQUE [J].
CONNELLY, A ;
COUNSELL, C ;
LOHMAN, JAB ;
ORDIDGE, RJ .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :519-525
[5]   A COMPARISON OF ONE-SHOT AND RECOVERY METHODS IN T1-IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :23-34
[6]  
Delpuech, 1980, PRACTICAL NMR SPECTR
[7]   INVIVO MEASUREMENTS OF VASCULAR OXYGEN-TENSION IN TUMORS USING MRI OF A FLUORINATED BLOOD SUBSTITUTE [J].
FISHMAN, JE ;
JOSEPH, PM ;
CARVLIN, MJ ;
SAADIELMANDJRA, M ;
MUKHERJI, B ;
SLOVITER, HA .
INVESTIGATIVE RADIOLOGY, 1989, 24 (01) :65-71
[8]   LOCALIZED PROTON SPECTROSCOPY USING STIMULATED ECHOES [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (03) :502-508
[9]   LOCALIZED PROTON NMR-SPECTROSCOPY IN DIFFERENT REGIONS OF THE HUMAN-BRAIN INVIVO - RELAXATION-TIMES AND CONCENTRATIONS OF CEREBRAL METABOLITES [J].
FRAHM, J ;
BRUHN, H ;
GYNGELL, ML ;
MERBOLDT, KD ;
HANICKE, W ;
SAUTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) :47-63
[10]   INVERSION RECOVERY SNAPSHOT FLASH MR IMAGING [J].
HAASE, A ;
MATTHAEI, D ;
BARTKOWSKI, R ;
DUHMKE, E ;
LEIBFRITZ, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (06) :1036-1040