HEMOSTASIS AFTER PARTIAL-HEPATECTOMY USING ARGON BEAM COAGULATION

被引:44
作者
POSTEMA, RR
PLAISIER, PW
TENKATE, FJW
TERPSTRA, OT
机构
[1] ERASMUS UNIV ROTTERDAM,EXPTL SURG LAB,ROTTERDAM,NETHERLANDS
[2] UNIV HOSP DIJKZIGT,DEPT GEN SURG,3015 GD ROTTERDAM,NETHERLANDS
[3] UNIV HOSP DIJKZIGT,DEPT PATHOL,3015 GD ROTTERDAM,NETHERLANDS
[4] UNIV HOSP LEIDEN,DEPT GEN SURG,2300 RC LEIDEN,NETHERLANDS
关键词
D O I
10.1002/bjs.1800801224
中图分类号
R61 [外科手术学];
学科分类号
摘要
The argon beam coagulator is a new device for haemostasis during and after surgery on parenchymatous organs. No data are available on its efficacy and tissue effect following hepatic resection. Blood loss, the time needed to achieve adequate haemostasis and histological findings after liver resection were assessed in 12 pigs using argon beam coagulation or suture ligation only, the mattress suture technique and tissue glue application. The treatment was randomly assigned to each of the four liver lobes in each pig. Median blood loss following argon beam coagulation was 13 (range 2-47) mi and after simple suture ligation 55 (range 2-260) ml(P<0.02). The median time needed for adequate haemostasis following argon beam coagulation was 3 (range 2-7) min versus 14 (range 2-48) min in the control group (P<0.005). There was no difference between argon beam coagulation and tissue glue, which were both superior to the use of mattress sutures. Argon beam coagulation resulted in less tissue damage than tissue glue or mattress suturing. The argon beam coagulator is an efficient device for achieving haemostasis following partial hepatectomy in the pig. rt causes only a moderate tissue reaction.
引用
收藏
页码:1563 / 1565
页数:3
相关论文
共 6 条
[1]   ELECTROSURGICAL DEBULKING OF OVARIAN-CANCER - A NEW TECHNIQUE USING THE ARGON BEAM COAGULATOR [J].
BRAND, E ;
PEARLMAN, N .
GYNECOLOGIC ONCOLOGY, 1990, 39 (02) :115-118
[2]   A CONTROLLED-STUDY OF THE ARGON BEAM COAGULATOR FOR PARTIAL NEPHRECTOMY [J].
HERNANDEZ, AD ;
SMITH, JA ;
JEPPSON, KG ;
TERREROS, DA .
JOURNAL OF UROLOGY, 1990, 143 (05) :1062-1065
[3]   USE OF FIBRIN GLUE IN HEPATIC-TRAUMA [J].
KRAM, HB ;
REUBEN, BI ;
FLEMING, AW ;
SHOEMAKER, WC .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1988, 28 (08) :1195-1201
[4]  
OTTOW RT, 1985, SURGERY, V97, P596
[5]  
TZUZUKI T, 1972, SURGERY, V72, P395
[6]  
WARD PH, 1989, ARCH OTOLARYNGOL, V115, P921