X-ray imaging using amorphous selenium: Photoinduced discharge (PID) readout for digital general radiography

被引:22
作者
Rowlands, JA
Hunter, DM
机构
[1] Sunnvbrook Health Sciences Centre, Medical Imaging Research, Reichmann Research Building, University of Toronto, Toronto, Ontario, M4N 3M5
关键词
digital radiography; fluoroscopy; photoconductor; amorphous selenium;
D O I
10.1118/1.597644
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital radiographic systems based on photoconductive layers with the latent charge image readout by photoinduced discharge (PID) are investigated theoretically. Previously, a number of different systems have been proposed using sandwiched photoconductor and insulator layers and readout using a scanning laser beam. These systems are shown to have the general property of being very closely coupled (i.e., optimization of one imaging characteristic usually impacts negatively on others). The presence of a condensed state insulator between the photoconductor surface and the readout electrode does, however, confer a great advantage over systems using air gaps with their relatively low breakdown field. The greater breakdown field of condensed state dielectrics permits the modification of the electric field during the period between image formation and image readout. The trade-off between readout speed and noise makes this system suitable for instant general radiography and even rapid sequence radiography, however, the system is unsuitable for the low exposure rates used in fluoroscopy.
引用
收藏
页码:1983 / 1996
页数:14
相关论文
共 33 条
[1]  
ANTONUK LE, 1992, P SOC PHOTO-OPT INS, V1651, P94, DOI 10.1117/12.59387
[2]   CHARGE-CARRIER DYNAMICS FOLLOWING PULSED PHOTOINJECTION [J].
BATRA, IP ;
KANAZAWA, KK ;
SCHECHTMAN, BH ;
SEKI, H .
JOURNAL OF APPLIED PHYSICS, 1971, 42 (03) :1124-+
[3]   XERORADIOGRAPHY [J].
BOAG, JW .
PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01) :3-37
[4]   RADIOGRAPHIC INFORMATION-THEORY AND APPLICATION TO MAMMOGRAPHY [J].
BRODIE, I ;
GUTCHECK, RA .
MEDICAL PHYSICS, 1982, 9 (01) :79-95
[5]   MINIMUM ENTRANCE EXPOSURE ESTIMATES FOR INFORMATION RECORDING IN DIAGNOSTIC-RADIOLOGY [J].
BRODIE, I ;
GUTCHECK, RA .
MEDICAL PHYSICS, 1985, 12 (03) :362-367
[6]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .1. AUTOMATED DETECTION OF MICROCALCIFICATIONS IN MAMMOGRAPHY [J].
CHAN, HP ;
DOI, K ;
GALHOTRA, S ;
VYBORNY, CJ ;
MACMAHON, H ;
JOKICH, PM .
MEDICAL PHYSICS, 1987, 14 (04) :538-548
[7]  
CHEN I, 1972, IEEE T ELECTRON DEV, VED19, P413, DOI 10.1109/T-ED.1972.17437
[8]  
CONRADS N, 1992, Patent No. 5132541
[9]  
COOK EL, 1994, 47TH SOC IM SCI TECH, P699
[10]   A NEW PHOTOCONDUCTOR IMAGING-SYSTEM FOR DIGITAL RADIOGRAPHY [J].
DEMONTS, H ;
BEAUMONT, F .
MEDICAL PHYSICS, 1989, 16 (01) :105-109