SURGICAL EXPERIENCE WITH DEFIBRILLATOR IMPLANTATION USING NONTHORACOTOMY LEADS

被引:19
作者
HAMMEL, D [1 ]
BLOCK, M [1 ]
KONERTZ, W [1 ]
BORGGREFE, M [1 ]
ISBRUCH, F [1 ]
ASFOUR, B [1 ]
GEIGER, A [1 ]
BREITHARDT, G [1 ]
SCHELD, HH [1 ]
机构
[1] HOSP UNIV MUENSTER,DEPT THORAC & CARDIOVASC,W-4400 MUNSTER,GERMANY
关键词
D O I
10.1016/0003-4975(93)90276-N
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Between October 10, 1989, and June 17, 1991, 109 patients with life-threatening ventricular arrhythmias received an implantable cardioverter-defibrillator at our institution. In 50 patients, nonthoracotomy lead systems consisting of a subcutaneous chest wall patch electrode near the cardiac apex and one (Cardiac Pacemakers, Inc: Endotak C) or two (Medtronic: Transvene) transvenous electrodes were tested. The mean ejection fraction was 0.44 +/- 0.15 with a range from 0.19 to 0.81. Twenty-four patients had a history of open heart operation. In 43 patients the nonthoracotomy lead system was implanted, whereas in 7 patients epicardial patch lead systems were required due to elevated defibrillation thresholds during nonthoracotomy lead testing. There was one perioperative death unrelated to the operative procedure (hydrocephalus internus). Hemorrhage from the subcutaneous patch pocket or the device pocket that required reintervention occurred in 4 patients. During a mean follow-up of 13 +/-5 months (range, 4 to 26 months) no dislocation of an endocardial lead, insulation defect, or lead fracture has been observed. In 1 patient, the lead system had to be removed due to infection of the subcutaneous patch pocket. The cardiovascular survival rate was 98% at 12 and 18 months, and freedom from sudden cardiac death was 100% at 6 and 12 months. In conclusion, defibrillator implantation using nonthoracotomy lead systems is feasible with a success rate of 86%, and during short-term follow-up no problems related to the lead system such as dislocation, fracture, or insulation defect have occurred.
引用
收藏
页码:685 / 693
页数:9
相关论文
共 28 条
  • [1] CONSTRICTIVE PERICARDITIS ASSOCIATED WITH PATCH ELECTRODES OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    ALMASSI, GH
    CHAPMAN, PD
    TROUP, PJ
    WETHERBEE, JN
    OLINGER, GN
    [J]. CHEST, 1987, 92 (02) : 369 - 371
  • [2] BACH S M JR, 1989, Journal of the American College of Cardiology, V13, p65A
  • [3] BARBOLA J, 1988, ARCH INTERN MED, V148, P70
  • [4] TRANSVENOUS DEFIBRILLATION IN HUMANS VIA THE CORONARY SINUS
    BARDY, GH
    ALLEN, MD
    MEHRA, R
    JOHNSON, G
    FELDMAN, S
    GREENE, HL
    IVEY, TD
    [J]. CIRCULATION, 1990, 81 (04) : 1252 - 1259
  • [5] BLOCK M, 1991, Z KARDIOL, V80, P657
  • [6] TRANSVENOUS, TRANSMEDIASTINAL, AND TRANSTHORACIC VENTRICULAR PACING - COMPARISON AFTER COMPLETE 2-YEAR FOLLOW-UP
    BRENNER, AS
    ANDERSON, ST
    ROSATI, RA
    MORRIS, JJ
    WAGNER, GS
    [J]. CIRCULATION, 1974, 49 (03) : 407 - 414
  • [7] CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    ECHT, DS
    ARMSTRONG, K
    SCHMIDT, P
    OYER, PE
    STINSON, EB
    WINKLE, RA
    [J]. CIRCULATION, 1985, 71 (02) : 289 - 296
  • [8] EPSTEIN AE, 1990, AICD ADV, V1, P12
  • [9] SUCCESS OF CHRONIC DEFIBRILLATION AND THE ROLE OF ANTIARRHYTHMIC DRUGS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    GUARNIERI, T
    LEVINE, JH
    VELTRI, EP
    GRIFFITH, LSC
    WATKINS, L
    JUANTEGUY, J
    MOWER, MM
    MIROWSKI, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (13) : 1061 - 1064
  • [10] IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (ICD) - A NEW LEAD-SYSTEM USING TRANSVENOUS-SUBCUTANEOUS APPROACH IN PATIENTS WITH PRIOR CARDIAC-SURGERY
    HAMMEL, D
    BLOCK, M
    HACHENBERG, T
    BORGGREFE, M
    BUDDE, T
    SOEPARWATA, R
    KONERTZ, W
    HIEF, C
    GEYWITZ, HJ
    BREITHARDT, G
    SCHELD, HH
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (06) : 315 - 318