KINETIC ASSAY OF ENZYMES WITH AN AMMONIA GAS-SENSING ELECTRODE .2. INSITU MONITORING OF SERUM LEUCINE AMINOPEPTIDASE

被引:4
作者
HATO, M
NAKAYAMA, H
SHIMURA, Y
机构
关键词
D O I
10.1016/S0003-2670(00)83176-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:203 / 208
页数:6
相关论文
共 15 条
[1]  
BAIULESCU GE, 1977, APPLICATIONS ION SEL, P156
[2]  
BOWERS LD, 1976, ANAL CHEM, V48, pA544
[3]  
FUJII S, 1975, Tokushima Journal of Experimental Medicine, V22, P1
[4]   THE MEASUREMENT OF ACTIVITY OF LEUCINE AMINOPEPTIDASE IN SERUM, URINE, BILE, AND TISSUES [J].
GOLDBARG, JA ;
PINEDA, EP ;
RUTENBURG, AM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1959, 32 (06) :571-575
[5]  
GUILBAULT GG, 1976, HDB ENZYMATIC METHOD, P137
[6]   KINETIC ASSAY OF ENZYMES WITH AN AMMONIA GAS-SENSING ELECTRODE .1. DYNAMIC-RESPONSES OF THE SENSOR [J].
HATO, M ;
MASUOKA, T ;
SHIMURA, Y .
ANALYTICA CHIMICA ACTA, 1983, 149 (MAY) :193-202
[7]   AUTOMATED ADENOSINE-DEAMINASE ENZYME DETERMINATION WITH AN AMMONIA-SENSING MEMBRANE ELECTRODE [J].
HJEMDAHLMONSEN, CE ;
PAPASTATHOPOULOS, DS ;
RECHNITZ, GA .
ANALYTICA CHIMICA ACTA, 1977, 88 (02) :253-259
[8]  
ITO S, 1977, J EXP MED, V24, P33
[9]  
LAKSHMINARAYANA.N, 1976, MEMBRANE ELECTRODES, P315
[10]   ENZYME ANALYSIS BY MEANS OF AIR-GAP ELECTRODE - DETERMINATION OF UREASE AND ARGINASE BY MONITORING OF INITIAL REACTION-RATE [J].
LARSEN, NR ;
HANSEN, EH ;
GUILBAULT, GG .
ANALYTICA CHIMICA ACTA, 1975, 79 (OCT) :9-15