COMPARISON OF DIGITAL BLOOD-PRESSURE, PLETHYSMOGRAPHY, AND THE MODIFIED ALLEN TEST AS MEANS OF EVALUATING THE COLLATERAL CIRCULATION TO THE HAND

被引:18
作者
FUHRMAN, TM
REILLEY, TE
PIPPIN, WD
机构
[1] Department of Anesthesiology, Ohio State University, Columbus, Ohio, 43210, N429 Doan Hall
[2] Department of Anesthesiology, The Ohio State University, Columbus, Ohio, 43210, N429 Doan Hall
[3] Department of Anesthesiology, The Ohio State University, Columbus, Ohio, 43210, N429 Doan Hall
关键词
ARTERIES; ALLEN TEST; MEASUREMENT TECHNIQUES; OXIMETRY; EQUIPMENT; FINAPRES;
D O I
10.1111/j.1365-2044.1992.tb03198.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The collateral circulation to the hand was evaluated on 70 hands of healthy volunteers. Comparisons were made between the results of the modified Allen's test alone and the Allen's test combined with either plethysmography or digital blood pressure. The modified Allen's test requires patient cooperation and the results can be subjective. Plethysmography does not require patient cooperation and produces a signal that varies directly with flow; however, this is not a quantifiable signal. Digital blood pressure (measured by the 2300 Finapres noninvasive blood pressure monitor, Ohmeda, Englewood, CO, USA) also requires no patient cooperation. The values produced are of clinical value and reproducible. Both the plethysmograph and digital blood pressure monitors were able to demonstrate the dominant arterial vessel of the hand. The digital blood pressure monitor produces an objective recordable numerical value, an accepted clinical parameter, and it does not require patient cooperation. The use of a digital blood pressure monitor may prove to be an acceptable alternative to the traditional Allen's test. Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:959 / 961
页数:3
相关论文
共 21 条
[1]  
ALLEN EV, 1929, AM J MED SCI, V17, P237
[2]  
BOEHMER RD, 1987, J CLIN MONITOR, V3, P282
[3]  
Breiman L, 2017, CLASSIFICATION REGRE, P368, DOI 10.1201/9781315139470
[4]   SIMPLE METHOD TO DETERMINE PATENCY OF ULNAR ARTERY INTRAOPERATIVELY PRIOR TO RADIAL-ARTERY CANNULATION [J].
BRODSKY, JB .
ANESTHESIOLOGY, 1975, 42 (05) :626-627
[5]   PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANESTHESIA - APPLICATION AND INTERPRETATION [J].
DORLAS, JC ;
NIJBOER, JA .
BRITISH JOURNAL OF ANAESTHESIA, 1985, 57 (05) :524-530
[6]  
DOWNS AR, 1975, SURGERY, V77, P530
[7]   EVALUATION OF COLLATERAL CIRCULATION OF THE HAND [J].
FUHRMAN, TM ;
PIPPIN, WD ;
TALMAGE, LA ;
REILLEY, TE .
JOURNAL OF CLINICAL MONITORING, 1992, 8 (01) :28-32
[8]   ASSESSING COLLATERAL CIRCULATION IN THE HAND - 4 METHODS COMPARED [J].
GLAVIN, RJ ;
JONES, HM .
ANAESTHESIA, 1989, 44 (07) :594-595
[9]   INCORRECT PERFORMANCE OF ALLENS TEST - ULNAR-ARTERY FLOW ERRONEOUSLY PRESUMED INADEQUATE [J].
GREENHOW, DE .
ANESTHESIOLOGY, 1972, 37 (03) :356-&