MULTIELEMENTAL ANALYSIS OF ENVIRONMENTAL MATRICES BY LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:32
作者
DURRANT, SF [1 ]
机构
[1] UNIV SURREY,DEPT CHEM,GUILDFORD GU2 5XH,SURREY,ENGLAND
关键词
LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; CERTIFIED REFERENCE MATERIAL; PEPPERBUSH; TEA LEAVES; MILK POWDER AND SEDIMENTS;
D O I
10.1039/an9921701585
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Laser ablation has been applied to the solid sample introduction into an inductively coupled plasma mass spectrometer for the multi-elemental analysis of several environmental matrices. Fourteen elements (Al, P, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr, Ba, Pb) were determined in the Japanese National Institute of Environmental Studies certified reference materials (CRMs) No. 7 Tea Leaves and No. 1 Pepperbush; nine elements (Na, Mg, Al, P, K, Cr, Mn, Fe, Zn) were determined in International Atomic Energy Agency CRM Al 1 Milk Powder; and 41 elements (Li, B, Sc, Ti, V, Cr, Mn, Co, Ni, Cu, Zn, Ga, Ge, As, Rb, Sr, Y, Zr, Nb, Mo, Sn, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Yb, Ta, W, Pb, Bi, Th, U) were determined in reference sediments GSD-2-GSD-8 from the Chinese Institute of Geophysical and Geochemical Prospecting. Calibrations were based on individual elemental sensitivities derived from matrix-matched standards. Simple and full internal standardization on a minor isotope of a major matrix element are discussed. The former are helpful for analysis of the biological matrices, but the latter do not improve precisions. Comparison with certified values shows fairly good accuracy, especially considering the rapidity of the analyses. The geological analyses were particularly successful as virtually no sample preparation was necessary and the analytical results obtained were very encouraging; detection limits for each type of analysis are given.
引用
收藏
页码:1585 / 1592
页数:8
相关论文
共 20 条
[1]   DETERMINATION OF TRACE-METALS IN MARINE BIOLOGICAL REFERENCE MATERIALS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
WILLIE, SN ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1988, 60 (07) :687-691
[2]   RESULTS OF A COORDINATED RESEARCH-PROGRAM TO IMPROVE THE CERTIFICATION OF IAEA MILK POWDER A-11 AND ANIMAL MUSCLE H-4 FOR 11 DIFFICULT TRACE-ELEMENTS [J].
BYRNE, AR ;
CAMARARICA, C ;
CORNELIS, R ;
DEGOEIJ, JJM ;
IYENGAR, GV ;
KIRKBRIGHT, G ;
KNAPP, G ;
PARR, RM ;
STOEPPLER, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (07) :723-729
[3]   DEVELOPMENT PROGRESS IN PLASMA SOURCE-MASS SPECTROMETRY [J].
DATE, AR ;
GRAY, AL .
ANALYST, 1983, 108 (1283) :159-165
[4]  
DURRANT SF, 1991, BRAZILIAN J VACUUM A, V10, P39
[5]  
DURRANT SF, UNPUB J ANAL CHEM
[6]  
DURRANT SF, 1989, THESIS U SURREY GUIL
[9]   INDUCTIVELY COUPLED PLASMA SOURCE-MASS SPECTROMETRY USING CONTINUUM FLOW ION EXTRACTION [J].
GRAY, AL ;
DATE, AR .
ANALYST, 1983, 108 (1290) :1033-1050
[10]  
Iida Y., 1991, J ANAL ATOM SPECTROM, V6, P541