A new parallel processing uninterruptible power supply (UPS) configuration is proposed in this paper. It provides active power line conditioning to minimize mains current distortion, This performance is superior to a conventional UPS, A prototype has been implemented and tested to verify its performance. The experimental results show that the input power factor of the proposed UPS is nearly unity, and the total harmonic distortion (THD) of the input current under nonlinear loading is only 3.618% for a mains voltage with THD of 1.633%.
引用
收藏
页码:629 / 635
页数:7
相关论文
共 21 条
[1]  
Grady W.M., Samotyj M.J., Noyola A.H., Survey of active power line conditioning methodlogies, IEEE Trans. Power Delivery, 5, 3, pp. 1536-1542, (1990)
[2]  
Takeda M., Ikeda K., Teramoto A., Aritsuka T., Harmonic current and reactive power compensation with an active filter, IEEE PESC'88 Rec., pp. 1174-1179, (1988)
[3]  
Cox M.D., Mirbod A., A new static VAR compensator for arc furnace, IEEE Trans. Power Syst., PWRS-1, 3, pp. 110-119, (1986)
[4]  
Choe G.H., Park M.H., A new injection method for ac harmonic elimination by active power filter, IEEE Trans. Ind. Electron., 35, 1, pp. 141-147, (1988)
[5]  
Harashima F., Inaba H., Tsuboi K., A closed-loop control for the reduction of reactive power required by electronic converters, IEEE Trans. Ind. Electron. Contr. Instrument, IECI-23, 2, pp. 162-166, (1976)
[6]  
Furuhashi T., Okuma S., Uchikama Y., A study on the theory of instantaneous reactive power, IEEE Trans. Ind. Electron., 37, 1, pp. 86-89, (1990)
[7]  
Akagi H., Kanazawa Y., Nabae A., Instataneous reactive power compensators comprising switching devices without energy storage components, IEEE Trans. Ind. Applicat., IA-20, 3, pp. 625-630, (1984)
[8]  
Peng F.Z., Akagi H., Nabae A., A study of active power filters using quard-series voltage-source PWM converters for harmonic compensation, IEEE Trans. Power Electron., 5, 1, pp. 9-15, (1990)
[9]  
Akagi H., Nabae A., Atoh S., Control strategy of active power filters using multiple voltage-source PWM converters, IEEE Trans. Ind. Applicat., IA-22, 3, pp. 460-465, (1986)
[10]  
Kawabata T., Miyashita T., Sashida N., Yamamoto Y., Three phase parallel processing UPS using multi-functional inverter, Proc. IEEE IAS, pp. 982-987, (1989)