A PERFLUOROSULFONATED IONOMER END-COLUMN ELECTRICAL DECOUPLER FOR CAPILLARY ELECTROPHORESIS/ELECTROCHEMICAL DETECTION

被引:39
作者
PARK, S
LUNTE, CE
机构
[1] UNIV KANSAS,DEPT CHEM,LAWRENCE,KS 66045
[2] UNIV KANSAS,CTR BIOANALYT RES,LAWRENCE,KS 66045
关键词
D O I
10.1021/ac00119a026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An end-column electrical decoupler constructed with perfluorosulfonated ionomer (Nafion) is described. This decoupler was fabricated at the cathodic end of the separation capillary by casting liquid Nafion ion exchange powder over a copper-plated tungsten wire. The internal diameter of the now channel was controlled by adjusting the thickness of the copper plating. This design overcomes problems of conventional end-column detection such as low sensitivity due to low collection efficiency of analytes at the detection electrode, difficulty in precise placement of the detection electrode, and the need to use small-bore capillaries (less than or equal to 25 mu m). The loss of cationic analytes observed with long-cast Nafion on-column decouplers was significantly reduced. The high current shunting capability of the long Nafion decoupler was maintained in this configuration. Elimination of the detection capillary required for on-column electrical decouplers provided higher separation efficiency by maintaining plug-type now throughout the system. Four model catecholamines were well separated within 5 min with separation efficiency of up to 230 000 plates and migration time reproducibilities of <0.6% RSD. With the optimized experimental conditions, detection limits of 3 nM for the catecholamines were achieved in a Ringer's solution matrix (to model a microdialysis sample).
引用
收藏
页码:4366 / 4370
页数:5
相关论文
共 18 条
[1]  
Wallingford R.A., Olefirowicz T.M., Ewing A.G., Anal. Chem., 61, pp. 292A-303A, (1989)
[2]  
Gozel P., Gassman N.E., Michelsen H., Zare R.N., Anal. Chem., 59, pp. 44-49, (1987)
[3]  
Wu S., Dovichi N.J., J. Chromatogr., 480, pp. 141-155, (1989)
[4]  
Ewing A.G., Mesaros J.M., Gavin P.F., Anal. Chem., 66, pp. 527A-537A, (1994)
[5]  
Wallingford R.A., Ewing A.G., Anal. Chem., 59, pp. 1762-1766, (1987)
[6]  
Huang X., Zare R.N., Anal. Chem., 62, pp. 443-446, (1990)
[7]  
Yike Y.F., Lee S.F., Khoo S.B., J. Chromatogr., 585, pp. 139-144, (1991)
[8]  
O'Shea T.J., Greenhagen R.D., Lunte S.M., Lunte C.E., Smyth M.R., Radzik D.M., Watanabe N., J. Chromatogr., 593, pp. 305-312, (1992)
[9]  
Lu W., Cassidy R.M., Anal. Chem., 66, pp. 200-204, (1994)
[10]  
Linhares M.C., Kissinger P.T., Anal. Chem., 63, pp. 2076-2078, (1991)