Operation and application of tissue-equivalent proportional counters

被引:35
作者
Gerdung, S
Pihet, P
Grindborg, JE
Roos, H
Schrewe, UJ
Schuhmacher, H
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a082805
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The application of TEPCs during the past decades in dosimetry, radiation protection and radiation therapy has revealed their large potential but also the necessity of careful operation. This paper reviews the experience gathered in the past and summarises the experimental procedures to ensure proper TEPC operation. The measurement system is described including detector, electronics and quality assurance. The pulse height analysis and its interpretation in terms of microdosimetric spectra and mean values are presented as well as the variance method. On the basis of these evaluation procedures, the second pan of the paper presents some typical examples of TEPC applications: dose spectrometry, time-of-flight techniques and the measurement of dose equivalent quantities. Special attention is paid to possible extensions but also to limitations of the use of TEPCs in the various fields of application.
引用
收藏
页码:381 / 404
页数:24
相关论文
共 89 条
[1]   CALIBRATING AND TESTING TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS WITH AR-37 [J].
ANACHKOVA, E ;
KELLERER, AM ;
ROOS, H .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1994, 33 (04) :353-364
[2]   DEVELOPMENT OF A PORTABLE MICRODOSIMETRIC RADIATION PROTECTION MONITOR COVERING A DYNAMIC-RANGE OF 120 DB ABOVE NOISE [J].
ARBEL, A ;
BOOZ, J ;
MULLER, KD ;
NEUHAUSS, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :691-696
[3]  
BENGTSSON LG, 1970, 2ND P S MICR, P375
[4]  
BINNS PJ, 1992, RADIAT PROT DOSIM, V44, P67
[5]  
BOOZ JJ, 1984, RAD PROT DOSIM, V9
[6]   Practical considerations in the design and construction of tissue-equivalent proportional counters [J].
Braby, LA ;
Johnson, GW ;
Barthe, J .
RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) :351-379
[7]  
BRACKENBUSH LW, 1989, RADIAT PROT DOSIM, V29, P119
[8]   SUMMARY OF MONOENERGETIC NEUTRON BEAM SOURCES FOR ENERGIES GREATER-THAN 14 MEV [J].
BRADY, FP ;
ROMERO, JL .
NUCLEAR SCIENCE AND ENGINEERING, 1990, 106 (03) :318-331
[9]   THE VARIANCE-COVARIANCE METHOD - MICRODOSIMETRY IN TIME-VARYING LOW DOSE-RATE RADIATION-FIELDS [J].
BRECKOW, J ;
WENNING, A ;
ROOS, H ;
KELLERER, AM .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1988, 27 (04) :247-259
[10]   NEUTRON KERMA FACTORS FOR MAGNESIUM AND ALUMINUM MEASURED WITH LOW-PRESSURE PROPORTIONAL-COUNTERS [J].
BUHLER, G ;
MENZEL, HG ;
SCHUHMACHER, H ;
DIETZE, G ;
GULDBAKKE, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (06) :601-611