A CALORIMETER FOR NEUTRON-FLUX MEASUREMENT

被引:8
作者
RICHARDSON, JM [1 ]
CHUPP, TE [1 ]
ROBERTSON, RGH [1 ]
WILKERSON, JF [1 ]
机构
[1] UNIV CALIF LOS ALAMOS SCI LAB,LOS ALAMOS,NM 87545
基金
美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(91)90335-N
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A calorimeter for absolute neutron flux measurement has been built and tested. The calorimeter measures the heat produced when neutrons are captured via the Li-6(n, H-3)He-4 reaction. The sensitivity achieved was 1.3 X 10(6) n/s for a 1 h measurement. Comparisons with a U-235 fission chamber are in agreement. An improved calorimeter is proposed which is designed to be sensitive to 10(5) n/s for a 1 h measurement.
引用
收藏
页码:291 / 299
页数:9
相关论文
共 14 条
[1]  
BONDARENKO LN, 1978, JETP LETT+, V28, P303
[2]   MEASUREMENT OF THE NEUTRON LIFETIME BY COUNTING TRAPPED PROTONS [J].
BYRNE, J ;
DAWBER, PG ;
SPAIN, JA ;
WILLIAMS, AP ;
DEWEY, MS ;
GILLIAM, DM ;
GREENE, GL ;
LAMAZE, GP ;
SCOTT, RD ;
PAUWELS, J ;
EYKENS, R ;
LAMBERTY, A .
PHYSICAL REVIEW LETTERS, 1990, 65 (03) :289-292
[3]   A NEW MEASUREMENT OF THE NEUTRON LIFETIME [J].
BYRNE, J ;
MORSE, J ;
SMITH, KF ;
SHAIKH, F ;
GREEN, K ;
GREENE, GL .
PHYSICS LETTERS B, 1980, 92 (3-4) :274-278
[4]  
CRISTENSEN CJ, 1972, PHYS REV D, V5, P1628
[5]   PREPARATION AND PROPERTIES OF LIPB, A NOVEL MATERIAL FOR SHIELDS AND COLLIMATORS [J].
FRIGERIO, NA ;
LAVOY, LL .
NUCLEAR TECHNOLOGY, 1971, 10 (03) :322-&
[6]  
GILLIAM D, 1986, NBS SPECIAL PUBLICAT, V711
[7]  
GILLIAM DM, COMMUNICATION
[8]  
GREENE G, COMMUNICATION
[9]  
LAST J, 1988, PHYS REV LETT, V60, P60
[10]   NEUTRON LIFETIME MEASURED WITH STORED ULTRACOLD NEUTRONS [J].
MAMPE, W ;
AGERON, P ;
BATES, C ;
PENDLEBURY, JM ;
STEYERL, A .
PHYSICAL REVIEW LETTERS, 1989, 63 (06) :593-596