RESPONSE CHARACTERISTICS OF CONDUCTIVE POLYMER COMPOSITE SUBSTRATE ALL-SOLID-STATE POLY(VINYL CHLORIDE) MATRIX MEMBRANE ION-SELECTIVE ELECTRODES IN AERATED AND NITROGEN-SATURATED SOLUTIONS

被引:37
作者
ALEGRET, S [1 ]
FLORIDO, A [1 ]
机构
[1] UNIV POLITECN CATALUNYA,ESCOLA TECN SUPER ENGINYERS IND BARCELONA,DEPT ENGINYERIA QUIM,E-08028 BARCELONA,SPAIN
关键词
ION-SELECTIVE ELECTRODE; PERCHLORATE; CONDUCTIVE EPOXY COMPOSITE-BASED ION-SELECTIVE ELECTRODE; CONDUCTING FILLED POLYMER-BASED ION-SELECTIVE ELECTRODE; ALL-SOLID-STATE POLY(VINYL CHLORIDE) MEMBRANE ELECTRODE;
D O I
10.1039/an9911600473
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The characterization of a perchlorate ion-selective electrode, with a poly(vinyl chloride) matrix membrane on a conductive silver-epoxy composite, showed that electrodes with this type of internal solid contact have virtually the same electrochemical properties as electrodes constructed with the same sensor system (methyltri-n-octylammonium perchlorate and 2-nitro-p-cymene as mediator solvent) or commercially available electrodes for perchlorate ion, both of which have internal liquid contacts. The constructed all-solid-state electrodes were studied under a variety of experimental conditions (sodium perchlorate solutions of different concentrations, pH and extent of aeration) in order to determine the actual limitations of electrodes based on conductive plastic composites. Owing to the internal solid contact, these electrodes give rise to small drifts in continuously de-aerated solutions. However, this disadvantage does not hinder direct potentiometric measurements.
引用
收藏
页码:473 / 476
页数:4
相关论文
共 28 条
  • [1] FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS
    ALEGRET, S
    ALONSO, J
    BARTROLI, J
    LIMA, JLFC
    MACHADO, AASC
    PAULIS, JM
    [J]. ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18): : 2291 - 2303
  • [2] FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS
    ALEGRET, S
    ALONSO, J
    BARTROLI, J
    PAULIS, JM
    LIMA, JLFC
    MACHADO, AASC
    [J]. ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) : 147 - 152
  • [3] BIOSENSORS BASED ON CONDUCTING FILLED POLYMER ALL-SOLID-STATE PVC MATRIX MEMBRANE ELECTRODES
    ALEGRET, S
    MARTINEZFABREGAS, E
    [J]. BIOSENSORS, 1989, 4 (05) : 287 - 297
  • [4] ALEGRET S, 1987, QUIM ANAL, V6, P278
  • [5] ALEGRET S, 1986, QUIM ANAL, V5, P36
  • [6] ALEGRET S, 1988, ANAL USES IMMOBILIZE, P309
  • [7] ALEGRET S, 1986, 2ND P INT M CHEM SEN, P751
  • [8] SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS
    ALONSO, J
    BARTROLI, J
    LIMA, JLFC
    MACHADO, AASC
    [J]. ANALYTICA CHIMICA ACTA, 1986, 179 : 503 - 508
  • [9] BUCK RP, 1980, ION SELECTIVE ELECTR, V2, P1
  • [10] SOME ALKYLPHOSPHORIC ACID-ESTERS FOR USE IN COATED-WIRE CALCIUM-SELECTIVE ELECTRODES .1. RESPONSE CHARACTERISTICS
    CATTRALL, RW
    DREW, DM
    HAMILTON, IC
    [J]. ANALYTICA CHIMICA ACTA, 1975, 76 (02) : 269 - 277