FORMATION AND DEGRADATION OF CHLORINATED AROMATIC-COMPOUNDS IN AN AIR-POLLUTION CONTROL DEVICE FOR MSW COMBUSTOR

被引:18
作者
MARKLUND, S
FANGMARK, I
RAPPE, C
机构
[1] Institute of Environmental Chemistry, University of Umeå, Umeå
关键词
D O I
10.1016/0045-6535(92)90498-G
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A municipal solid waste combustor (MWC) in Avesta Sweden, was equipped with an electrostatic precipitator (ESP), a dry scrubber (DS), a fabric filter (FF) and an additional add-on air pollution control system indcuding wet scrubber (WS) and a condensation device (CD). Higher levels of polychlorinated dioxins and dibenzofurans (PCDD/Fs) were found after the additional add-on air pollution control system than after the fabric filter. The results indicate a formation or a transformation of PCDD/Fs in the wet scrubber and in the condensation device.
引用
收藏
页码:139 / 142
页数:4
相关论文
共 5 条
[1]  
CARLSSON K, 1991, COMMUNICATION
[2]   RECOMMENDED METHODOLOGY FOR MEASUREMENTS OF PCDD AND PCDF IN THE NORDIC COUNTRIES [J].
JANSSON, B ;
BERGVALL, G .
WASTE MANAGEMENT & RESEARCH, 1987, 5 (03) :251-255
[3]  
MARKLUND S, 1991, 2ND ANN INT C MUN WA, P814
[4]  
MARKLUND S, 1990, THESIS U UMEA SWEDEN
[5]  
MARKLUND S, 1991, IN PRESS WASTE MANAG