ENDOSCOPIC PHOTOGRAPHIC COMPARISON OF DRUG DELIVERY BY EAR-DROPS AND BY AEROSOL SPRAY

被引:10
作者
MCGARRY, GW
SWAN, IRC
机构
[1] Department of Otolaryngology, Royal Infirmary, Glasgow
来源
CLINICAL OTOLARYNGOLOGY | 1992年 / 17卷 / 04期
关键词
EAR-DROPS; AEROSOL SPRAY; ENDOSCOPIC PHOTOGRAPHY;
D O I
10.1111/j.1365-2273.1992.tb01013.x
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The Otomize (Stafford-Miller Ltd) aerosol spray is a new device for delivering topical ear medication in otitis externa. Both the manufacturers and a recent study have claimed that the spray produces better coverage of the external ear canal than do traditional ear-drops. We performed an endoscopic photographic comparison study to investigate this claim. The area of tympanic membrane and ear canal covered with medication was greater in those ears treated with the aerosol (P < 0.001, paired t-test). The ability of the aerosol to deliver drug to the level of the tympanic membrane suggests a possible role for this device in the treatment of chronic otitis media. The technique of endoscopic photography provides an objective and reproducible means of investigating drug delivery systems for otological conditions.
引用
收藏
页码:359 / 360
页数:2
相关论文
共 1 条
[1]   DISTRIBUTION OF EAR DROPS USING A NON-AEROSOL SPRAY DELIVERY SYSTEM [J].
WILSON, PS ;
DINGLE, A ;
GROCUTT, M ;
REID, AP .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1991, 105 (08) :651-652