EFFECTS OF FILTERING ON RIGHT VENTRICULAR ELECTROGRAMS RECORDED FROM ENDOCARDIAL CATHETERS IN HUMANS

被引:14
作者
KLITZNER, TS
STEVENSON, WG
机构
[1] UNIV CALIF LOS ANGELES,DEPT PEDIAT,DIV CARDIOL,LOS ANGELES,CA 90024
[2] UNIV CALIF LOS ANGELES,DEPT MED,DIV CARDIOL,LOS ANGELES,CA 90024
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 01期
关键词
endocardial electrograms; mapping;
D O I
10.1111/j.1540-8159.1990.tb02005.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Criteria for identifying electrically abnormal myocardium based on analysis of electrogram, amplitude, duration, and morphology have recently been proposed as an aid to catheter mapping in humans. Electrogram characteristics are likely to be influenced by analog filtering and the distance between recording electrodes. These parameters can be varied and differ among electrophysiol‐ogy laboratories. To determine the magnitude of the effect of low pass and high pass filtering and intere‐lectrode distance on human bipolar right ventricular electrograms eight patients were studied. The signal from a single bipolar electrode pair was recorded simultaneously on five channels with variable filtering. As the high pass filter frequency increased above 10 Hz, the electrogram duration and amplitude decreased. The decrease in amplitude was described by a monoexponential function with a 30% decrease in amplitude at a filter setting of 30 Hz and a 69% decrease at a filter setting of 100 Hz. As the low pass filter frequency decreased from 2,500 to 250 Hz, electrogram characteristics were not significantly altered. Low pass filtering at 300 Hz decreased electrogram amplitude slightly. Neither high nor low pass filter settings or interelectrode distance affected electrogram timing. However, filtering could markedly alter electro‐gram morphology, introducing the possibility for errors in visual assessment of electrograms. Electrogram duration increased linearly with increasing distance between recording electrodes. The effects of filtering on electrograms were similar regardless of interelectrode spacing. Thus, varying the high pass filter setting over a range that is used clinically (from 1 to 100 Hz) can substantially alter electrogram duration, amplitude, and morphology. Low pass filtering at 250 Hz and above had no effect on these electrograms although it is possible that alterations would be observed in signals from areas of slow conduction that we did not study. The filter setting and interelectrode distance must be considered when applying proposed criteria for distinguishing normal from abnormal electrograms. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:69 / 77
页数:9
相关论文
共 17 条
[1]   REPRODUCIBILITY OF LOCAL ACTIVATION TIMES DURING INTRA-OPERATIVE EPICARDIAL MAPPING [J].
ABENDROTH, RR ;
OSTERMEYER, J ;
BREITHARDT, G ;
SEIPEL, L ;
BIRCKS, W .
CIRCULATION, 1980, 62 (01) :75-79
[2]   ENDOCARDIAL CATHETER MAPPING IN PATIENTS IN SINUS RHYTHM - RELATIONSHIP TO UNDERLYING HEART-DISEASE AND VENTRICULAR ARRHYTHMIAS [J].
CASSIDY, DM ;
VASSALLO, JA ;
MILLER, JM ;
POLL, DS ;
BUXTON, AE ;
MARCHLINSKI, FE ;
JOSEPHSON, ME .
CIRCULATION, 1986, 73 (04) :645-652
[3]   ENDOCARDIAL MAPPING IN HUMANS IN SINUS RHYTHM WITH NORMAL LEFT-VENTRICLES - ACTIVATION PATTERNS AND CHARACTERISTICS OF ELECTROGRAMS [J].
CASSIDY, DM ;
VASSALLO, JA ;
MARCHLINSKI, FE ;
BUXTON, AE ;
UNTEREKER, WJ ;
JOSEPHSON, ME .
CIRCULATION, 1984, 70 (01) :37-42
[4]   CATHETER MAPPING DURING SINUS RHYTHM - RELATION OF LOCAL ELECTROGRAM DURATION TO VENTRICULAR-TACHYCARDIA CYCLE LENGTH [J].
CASSIDY, DM ;
VASSALLO, JA ;
BUXTON, AE ;
DOHERTY, JU ;
MARCHLINSKI, FE ;
JOSEPHSON, ME .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (06) :713-716
[5]   EFFECTS OF DISTANT POTENTIALS ON UNIPOLAR ELECTROGRAMS IN AN ANIMAL-MODEL UTILIZING THE RIGHT VENTRICULAR ISOLATION PROCEDURE [J].
DAMIANO, RJ ;
BLANCHARD, SM ;
ASANO, T ;
COX, JL ;
LOWE, JE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (05) :1100-1109
[6]   COMPARISON OF UNIPOLAR AND BIPOLAR ELECTROGRAMS FOR CARDIAC-PACEMAKER SENSING [J].
DECAPRIO, V ;
HURZELER, P ;
FURMAN, S .
CIRCULATION, 1977, 56 (05) :750-755
[7]  
DECAPRIO V, 1976, MED INSTRUM, V10, P55
[8]   TECHNIQUES OF INTRA-OPERATIVE ELECTROPHYSIOLOGIC MAPPING [J].
GALLAGHER, JJ ;
KASELL, JH ;
COX, JL ;
SMITH, WM ;
IDEKER, RE ;
SMITH, WM .
AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (01) :221-240
[9]   ELECTROPHYSIOLOGIC AND ANATOMIC BASIS FOR FRACTIONATED ELECTROGRAMS RECORDED FROM HEALED MYOCARDIAL INFARCTS [J].
GARDNER, PI ;
URSELL, PC ;
FENOGLIO, JJ ;
WIT, AL .
CIRCULATION, 1985, 72 (03) :596-611
[10]   FRACTIONATED ELECTRICAL-ACTIVITY AND CONTINUOUS ELECTRICAL-ACTIVITY - FACT OR ARTIFACT [J].
JOSEPHSON, ME ;
WIT, AL .
CIRCULATION, 1984, 70 (04) :529-532