A MULTICENTER STUDY ON THE EFFICIENCY OF WHITE CELL REDUCTION BY FILTRATION OF RED-CELLS

被引:41
作者
MASSE, M
ANDREU, G
ANGUE, M
BABAULT, C
BEAUJEAN, F
BIDET, ML
BOUDART, D
CALOT, JP
COTTE, C
FOLLEA, G
GEROTA, J
HAU, F
HUREL, C
LEGRAND, E
MARCHESSEAU, B
NASR, O
ROBERT, F
ROYER, D
SCHOONEMAN, F
TARDIVEL, R
VIDAL, M
机构
[1] SECT HEMOBIOL TRANSFUS PITIE SALPETRIERE,DEPT PROD & CONTROL,PARIS,FRANCE
[2] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,TOURS,FRANCE
[3] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,CRETEIL,FRANCE
[4] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,ANGERS,FRANCE
[5] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,NANTES,FRANCE
[6] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,TOULOUSE,FRANCE
[7] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,BORDEAUX,FRANCE
[8] CTR NATL TRANSFUS SANGUINE,DEPT PROD & CONTROL,PARIS,FRANCE
[9] CTR DEPT TRANSFUS SANGUINE,DEPT PROD & CONTROL,ORLEANS,FRANCE
[10] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,LILLE,FRANCE
[11] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,MONTPELLIER,FRANCE
[12] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,LYONS,FRANCE
[13] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,ROUEN,FRANCE
[14] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,NANCY,FRANCE
[15] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,CLERMONT FERRAND,FRANCE
[16] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,RENNES,FRANCE
[17] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,STRASBOURG,FRANCE
[18] CTR REG TRANSFUS SANGUINE,DEPT PROD & CONTROL,MARSEILLE,FRANCE
关键词
D O I
10.1046/j.1537-2995.1991.31992094664.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate accurately the current performance of filtration, the French Produits Sanguins Labiles study group, composed of 21 transfusion teams, conducted a large-scale 6-month study involving over 1400 filtrations and 3000 controls. Some 745 standard red cell concentrates (RBC concentrates) and 690 concentrates previously white cell (WBC)-reduced by removal of buffy coat (BC-poor RBC concentrates) were filtered using six commercially available filters: at least 170 results were collected per filter, spread among a minimum of three teams. Prefiltration controls show that the removal (manual and automated) of the buffy coat results in an initial WBC reduction of approximately 63 percent, along with a hemoglobin loss Of 4 g (7%). After filtration, residual WBCs were counted in the Nageotte manual counting chamber. The reliability of this counting method, which is simple and adapted to low WBC concentration, was characterized in this study by a 25-percent coefficient of variation (CV) for a concentration of 2.5 WBCs per mu-L (i.e., 0.6 x 10(6) WBCs/filtered unit). The analysis of the results shows that, for five of six filters (1 filter was excluded), the postfiltration median value of residual WBCs was 1.1 x 10(6) in filtered RBC concentrates (n = 590), whereas it was 0.34 x 10(6) in filtered BC-poor RBC concentrates (n = 581). The difference is significant (p < 10(-8), Wilcoxon test). Hemoglobin loss due to filtration varies according to the filter, from 5.7 +/- 2.2 to 17.3 +/- 2.5 g. The study data confirm that the combination of prefiltration BC removal plus filtration results in a reduced number of residual WBCs (99% of filtered BC-poor RBC concentrates contained < 5 x 10(6) WBCs, as compared to only 81% of filtered RBC concentrates). However, these combined methods result in a significantly higher overall hemoglobin loss than filtration alone (10 g overall hemoglobin loss for filtration alone vs. 15 g for combination of BC removal plus filtration).
引用
收藏
页码:792 / 797
页数:6
相关论文
共 27 条
[1]  
ANDREU G, 1988, BLOOD, V72, P964
[2]   A FLOW CYTOMETRIC TECHNIQUE TO ACCURATELY MEASURE POST-FILTRATION WHITE BLOOD-CELL COUNTS [J].
BODENSTEINER, DC .
TRANSFUSION, 1989, 29 (07) :651-653
[3]  
DEGRAANHENTZEN YCE, 1989, TRANSFUSION, V29, P757
[4]   FLOW-CYTOMETRIC METHOD FOR COUNTING VERY LOW NUMBERS OF LEUKOCYTES IN PLATELET PRODUCTS [J].
DZIK, WH ;
RAGOSTA, A ;
CUSACK, WF .
VOX SANGUINIS, 1990, 59 (03) :153-159
[5]   ALLOIMMUNIZATION TO HLA ANTIGENS FOLLOWING TRANSFUSION WITH LEUKOCYTE-POOR AND PURIFIED PLATELET SUSPENSIONS [J].
FISHER, M ;
CHAPMAN, JR ;
TING, A ;
MORRIS, PJ .
VOX SANGUINIS, 1985, 49 (05) :331-335
[6]   WHITE CELL COUNTING IN RED-CELLS AND PLATELETS - HOW FEW CAN WE COUNT [J].
FRIEDMAN, LI ;
SADOFF, BJ ;
STROMBERG, RR .
TRANSFUSION, 1990, 30 (05) :387-389
[7]   PREVENTION OF TRANSFUSION-ACQUIRED CYTOMEGALO-VIRUS INFECTION IN INFANTS BY BLOOD FILTRATION TO REMOVE LEUKOCYTES [J].
GILBERT, GL ;
HUDSON, IL ;
HAYES, K ;
JAMES, J .
LANCET, 1989, 1 (8649) :1228-1231
[8]   STUDIES IN RED-BLOOD-CELL PRESERVATION .1. EFFECT OF THE OTHER FORMED ELEMENTS [J].
GREENWALT, TJ ;
SOSTOK, CZ ;
DUMASWALA, UJ .
VOX SANGUINIS, 1990, 58 (02) :85-89
[9]   A METHOD FOR COUNTING LEUKOCYTES IN FILTERED COMPONENTS [J].
GREENWALT, TJ ;
ALLEN, CM .
TRANSFUSION, 1990, 30 (04) :377-379
[10]  
HOGMAN CF, 1988, VOX SANG, V55, P211