BINDING OF A NEW MONOCLONAL-ANTIBODY AGAINST N-TERMINAL HEPTAPEPTIDE OF FIBRIN ALPHA-CHAIN TO FIBRIN POLYMERIZATION SITE-A - EFFECTS OF FIBRINOGEN AND FIBRINOGEN DERIVATIVES, AND PRETREATMENT OF SAMPLES WITH NASCN

被引:42
作者
DEMPFLE, CE [1 ]
DOLLMAN, M [1 ]
LILL, H [1 ]
PUZZOVIO, D [1 ]
DESSAUER, A [1 ]
HEENE, DL [1 ]
机构
[1] BOEHRINGER MANNHEIM GMBH, W-8132 TUTZING, GERMANY
关键词
FIBRINOGEN; FIBRIN; FIBRIN MONOMER; MONOCLONAL ANTIBODY; THIOCYANATE; DYSFIBRINOGENEMIA;
D O I
10.1097/00001721-199304010-00013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A novel murine monoclonal antibody against the fibrin alpha-chain N-terminus is presented, which reacts with desAA- and desAABB-fibrin. In immunoblot procedures, the antibody reacted with fibrin degradation products X and Y of non-crosslinked fibrin, and fragment E. No binding was observed to the fibrin fragment D-dimer, and fibrinogen fragments D and E. Minor binding to fibrinogen fragments X, and Y, and desBB-fibrin were presumably due to minor contamination with (desAA)-fibrin. A prerequisite for binding was release of fibrinopeptides A (FpA), the binding site being a fibrin-specific neo-epitope. No binding was observed to fibrinogen or to thrombin-treated dysfibrinogen MANNHEIM III (Aalpha 16 Arg-->Cys) molecules, which do not release FpA. The antibody bound to abnormal fibrin molecules prepared from dysfibrinogen MANNHEIM I (Aalpha19 Arg-->Gly), albeit to a lesser extent than to normal fibrin. Binding of the antibody to the fibrin epitope was greatly enhanced by denaturation, e.ga. by heat, or by treatment with chaotropic ions. Soluble fibrin in clinical samples is generally found as a complex with fibrinogen, since polymerization sites 'A' exposed by release of FpA react with complementary binding sites 'a' on the D-domains of other fibrin and fibrinogen molecules. Treatment of samples with NaSCN caused dissociation of fibrin monomer complexes. Reassociation was prevented by denaturation of both polymerization sites 'A' and 'a'. The antibody in combination with NaSCN-treatment of samples was useful for specific detection of fibrin monomer in plasma samples. Measurement was not influenced by fibrinogen degradation products, whereas fibrin degradation products at very high concentration caused some underestimation of fibrin monomer concentration.
引用
收藏
页码:79 / 86
页数:8
相关论文
共 26 条
[1]  
BLOMBACK B, 1988, EXCERPTA MED, V801, P263
[2]   FIBRINOGEN DETROIT - A MOLECULAR DEFECT IN N-TERMINAL DISULPHIDE KNOT OF HUMAN FIBRINOGEN [J].
BLOMBACK, M ;
BLOMBACK, B ;
MAMMEN, EF ;
PRASAD, AS .
NATURE, 1968, 218 (5137) :134-&
[3]   FIBRIN POLYMERIZATION SITES IN FIBRINOGEN AND FIBRIN FRAGMENTS [J].
BUDZYNSKI, AZ ;
OLEXA, SA ;
PANDYA, BV .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 408 (JUN) :301-314
[4]  
CIERNIEWSKI CS, 1986, J BIOL CHEM, V261, P9116
[5]  
DEMPFLE CE, 1992, J LAB CLIN MED, V119, P522
[6]   ISOLATION AND PURIFICATION OF FIBRINOGEN FIBRIN DEGRADATION PRODUCTS BY CHROMATOGRAPHY ON PROTAMINE-AGAROSE [J].
DEMPFLE, CE ;
HEENE, DL .
THROMBOSIS RESEARCH, 1987, 48 (02) :223-232
[7]   PURIFICATION OF HUMAN-PLASMA FIBRINOGEN BY CHROMATOGRAPHY ON PROTAMINE-AGAROSE [J].
DEMPFLE, CE ;
HEENE, DL .
THROMBOSIS RESEARCH, 1987, 46 (01) :19-27
[8]  
DEMPFLER CE, 1990, EXERPTA MED, V789, P159
[9]   EQUILIBRIA IN THE FIBRINOGEN-FIBRIN CONVERSION .2. REVERSIBILITY OF THE POLYMERIZATION STEPS [J].
DONNELLY, TH ;
LASKOWSKI, M ;
NOTLEY, N ;
SCHERAGA, HA .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1955, 56 (02) :369-387