ACCELEROMETER-BASED ADAPTIVE-RATE PACING - A MULTICENTER STUDY

被引:6
作者
CHARLES, RG
HEEMELS, JP
WESTRUM, BL
BLANC, P
BORST, UE
ECTOR, H
GRIEBENOW, R
JORDAENS, L
KUBLER, L
LANGENFELD, H
NIO, SL
RES, JCJ
STERTMANN, WA
TIMMERMANS, AJM
VERDEL, GJE
机构
[1] MED SPECTRUM TWENTE,ENSCHEDE,NETHERLANDS
[2] KENNEMER GASTHUIS,HAARLEM,NETHERLANDS
[3] CARDIAC PACEMAKERS INC EUROPE,LONDON,ENGLAND
[4] CARDIAC PACEMAKERS INC,ST PAUL,MN
[5] CHU LIMOGES,F-87031 LIMOGES,FRANCE
[6] UNIV MARBURG,MED KLIN,W-3550 MARBURG,GERMANY
[7] UNIV ZIEKENHUIS GASTHUISBERG,LOUVAIN,BELGIUM
[8] UNIV COLOGNE,MEDKLIN 2,COLOGNE,GERMANY
[9] UNIV ZIEKENHUIS GENT,GENT,GERMANY
[10] UNIV WURZBURG,MED KLIN,W-8700 WURZBURG,GERMANY
[11] IJSSELLAND ZIEKENHUIS,ROTTERDAM,NETHERLANDS
[12] UNIV AMSTERDAM,ACAD MED CTR,1105 AZ AMSTERDAM,NETHERLANDS
[13] UNIV KLIN GIESSEN,GIESSEN,GERMANY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 03期
关键词
ACCELEROMETER; CAEP; CHRONOTROPIC RESPONSE ZONE; MOTION; ADAPTIVE RATE PACEMAKER;
D O I
10.1111/j.1540-8159.1993.tb01604.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new adaptive rate pacemaker, using an accelerometer to detect body motion as an indicator of metabolic demand, was evaluated in 13 centers located in five countries. During the study, 55 patients with a broad range of indications were implanted with the EXCEL(TM) VR single chamber pacemaker. One month evaluations were completed on a subgroup of 37 patients. The pacemaker response was optimized before discharge using a simple walking test. An ''exercise test'' recording feature in the programmer eliminated the need for ECG monitoring. At nominal settings, the mean (+/- SD) pacing rate increased 29 +/- 9 ppm while walking slowly and 44 +/- 11 ppm (n = 33) during a brisk walk. This information was used to optimize the parameter settings. Without further changes to the programmed settings the patients were subsequently tested 2-4 weeks postimplant with a symptom-limited treadmill test using the chronotropic assessment exercise protocol (CAEP). Mean pacing rate increased from 74.5 +/- 2.5 ppm (n = 24) at rest to 118.6 +/- 12.2 ppm (n = 21) at 3 mph/6% grade to 143.5 +/- 2.5 ppm (n = 2) at 3.8 mph/8% grade. Conclusion. The individual responses were proportional to the physical exertion imposed on the patients. Pacing rates were considered to be appropriate using the chronotropic response zone as a criterion for appropriate rate modulation. A simple walking test utilizing the exercise test facility, results in appropriate optimization of the pulse generator to the individual patient.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 15 条
[1]  
ALLEN HV, 1989, SENSORS, V6, P9
[2]   THE BASIS FOR ACTIVITY CONTROLLED RATE VARIABLE CARDIAC-PACEMAKERS - AN ANALYSIS OF MECHANICAL FORCES ON THE HUMAN-BODY INDUCED BY EXERCISE AND ENVIRONMENT [J].
ALT, E ;
MATULA, M ;
THERES, H ;
HEINZ, M ;
BAKER, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (10) :1667-1680
[3]  
BUNGE T, 1985, CARDIAC PACING, P786
[4]  
FURMAN S, 1989, PRACTICE CARDIAC PAC, P387
[5]  
HOWE RT, 1990, IEEE SPECTRUM JUL, P29
[6]   SELECTIVE VIBRATION SENSING - A NEW CONCEPT FOR ACTIVITY-SENSING RATE-RESPONSIVE PACING [J].
LAU, CP ;
STOTT, JRR ;
TOFF, WD ;
ZETLEIN, MB ;
WARD, DE ;
CAMM, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (09) :1299-1309
[7]  
MATULA M, 1987, PACE, V10, P1220
[8]   PHYSIOLOGIC CORRELATES OF THE HEART-RATE RESPONSE TO UPRIGHT ISOTONIC EXERCISE - RELEVANCE TO RATE-RESPONSIVE PACEMAKERS [J].
MCELROY, PA ;
JANICKI, JS ;
WEBER, KT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (01) :94-99
[9]  
MILLERHAGEN J, 1990, PACE, V13, P1204
[10]  
Powers S., 1990, EXERCISE PHYSL THEOR, V2nd ed.