A MULTICHANNEL HOOK ELECTRODE FOR SIMULTANEOUS RECORDING OF UP TO 12 NERVE FILAMENTS

被引:14
作者
DJUPSJOBACKA, M
JOHANSSON, H
BERGENHEIM, M
SANDSTROM, U
机构
[1] NATL INST OCCUPAT HLTH,DIV WORK PHYSIOL,S-90713 UMEA,SWEDEN
[2] UMEA UNIV,DEPT PHYSIOL,S-90187 UMEA,SWEDEN
关键词
ELECTRODE; MULTIPLE; AG/AGCL; SIMULTANEOUS RECORDING; AFFERENT; SINGLE; SENSORY; MUSCLE; DORSAL ROOT; (CAT);
D O I
10.1016/0165-0270(94)90058-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes a simple multichannel hook electrode specially adapted for simultaneous recording from several dorsal root filaments in the cat. The electrode consists of a 3-mm-thick PVC plate and accommodates 12 silver wire hooks placed in notches in the plate. It has a semicircular shape, and the notches are milled radially in the plate. With this electrode we have made successful recordings of single-unit activity from 12 muscle afferents for periods of up to 8 h. In contrast to more rigid and complicated devices, e.g., developed to assess activity of populations of individual neurones from single-channel recordings of multi-unit activity, it also permits selection of the types of afferents to be recorded. The use of this simple device and an appropriate number of amplifiers and window discriminators can greatly enhance the quality of studies on populations of afferents in animals and may also decrease the number of laboratory animals needed.
引用
收藏
页码:69 / 72
页数:4
相关论文
共 7 条
[1]   MULTISITE MICROPROBES FOR NEURAL RECORDINGS [J].
BLUM, NA ;
CARKHUFF, BG ;
CHARLES, HK ;
EDWARDS, RL ;
MEYER, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (01) :68-74
[2]   OPTIMUM ELECTROLYTIC CHLORIDING OF SILVER ELECTRODES [J].
GEDDES, LA ;
BAKER, LE ;
MOORE, AG .
MEDICAL & BIOLOGICAL ENGINEERING, 1969, 7 (01) :49-&
[3]   THE RECONSTRUCTION OF INDIVIDUAL SPIKE TRAINS FROM EXTRACELLULAR MULTINEURON RECORDINGS USING A NEURAL NETWORK EMULATION PROGRAM [J].
JANSEN, RF .
JOURNAL OF NEUROSCIENCE METHODS, 1990, 35 (03) :203-213
[4]  
JOHANSSON H, 1991, CRIT REV BIOMED ENG, V18, P341
[5]  
JOHANSSON H, 1991, J PHYSIOL-PARIS, V85, P6
[6]   ADAPTATION OF THE REITBOECK METHOD OF MULTIPLE MICROELECTRODE RECORDING TO THE NEOCORTEX OF THE WAKING MONKEY [J].
MOUNTCASTLE, VB ;
REITBOECK, HJ ;
POGGIO, GF ;
STEINMETZ, MA .
JOURNAL OF NEUROSCIENCE METHODS, 1991, 36 (01) :77-84
[7]   A MULTIMICROELECTRODE SYSTEM COMPOSED OF INDEPENDENT GLASS MICROPIPETTES WITH AN ECCENTRIC TIP STRUCTURE FOR SIMULTANEOUS INTRACELLULAR-RECORDING [J].
SABURI, M ;
YAMADA, M ;
SHIGEMATSU, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :656-658