PRESSURE-TIME PRODUCT DURING CONTINUOUS POSITIVE AIRWAY PRESSURE, PRESSURE SUPPORT VENTILATION, AND T-PIECE DURING WEANING FROM MECHANICAL VENTILATION

被引:162
作者
SASSOON, CSH
LIGHT, RW
LODIA, R
SIECK, GC
MAHUTTE, CK
机构
[1] UNIV CALIF IRVINE,DEPT MED,IRVINE,CA 92717
[2] MAYO CLIN & MAYO FDN,DEPT BIOPHYS,ROCHESTER,MN 55905
[3] MAYO CLIN & MAYO FDN,DEPT ANESTHESIOL,ROCHESTER,MN 55905
[4] MAYO CLIN & MAYO FDN,DEPT PHYSIOL,ROCHESTER,MN 55905
来源
AMERICAN REVIEW OF RESPIRATORY DISEASE | 1991年 / 143卷 / 03期
关键词
D O I
10.1164/ajrccm/143.3.469
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The objective of this study was to compare the effects of continuous positive airway pressure (CPAP), pressure support ventilation (PS), and T-piece on the pressure-time product (PTP) during weaning from mechanical ventilation. The PTP is an estimate of the metabolic work or oxygen consumption of the respiratory muscles. We studied 10 intubated patients recovering from acute respiratory failure of various etiologies. A modified continous flow (flow-by) CPAP of 0 and 5 cm H2O (CPAP-0 and CPAP-5, respectively), PS of 5 cm H2O (PS-5), and T-piece were applied in random order for 30 min each. In the last 5 min of the 30-min periods, we measured the esophageal pressure and transdiaphragmatic pressure-time products-PTP(es) and PTP(di), cm H2O.s/min, respectively-multiplied by respiratory frequency. Breathing pattern, total lung resistance (RL), quasi-static lung compliance (CL), intrinsic positive end-expiratory pressure (PEEPi), end-expiratory transpulmonary pressure (Ptpexp), arterial blood gases, blood pressure, and heart rate were also measured. In comparison to T-piece, CPAP-5 decreased PTP(es) 40% (p < 0.01) and PTP(di) 43% (p < 0.02), whereas PS-5 decreased PTP(es) 34% (p < 0.01) and PTP(di) 38% 38% (p < 0.05). The decrease in PTP(es) with CPAP-5 was associated with a significant reduction in RL, and to a less extent in PEEPi relative to airway pressure. The contribution of the decrease in PEEPi to the reduction in PTP(es) amounted to 36%. With PS-5, respiratory system mechanics and PEEPi were not significantly different compared with T-piece. With CPAP-0, PTP tended to be lower than with T-piece. This was likely due to the inherent small end-inspiratory positive pressure related to the CPAP system. Breathing pattern, arterial blood gas measurements, and hemodynamics were similar in all the ventilatory modes. In conclusion, during weaning from mechanical ventilation of patients recovering from acute respiratory failure, low levels of CPAP and PS significantly decrease the pressure-time product by 40 and 34%, respectively, compared with T-piece.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 35 条
[1]  
AGOSTONI E, 1964, HANDBOOK PHYSIOLOG 3, V1, P387
[2]   DETRIMENTAL EFFECTS OF REMOVING END-EXPIRATORY PRESSURE PRIOR TO ENDOTRACHEAL EXTUBATION [J].
ANNEST, SJ ;
GOTTLIEB, M ;
PALOSKI, WH ;
STRATTON, H ;
NEWELL, JC ;
DUTTON, R ;
POWERS, SR .
ANNALS OF SURGERY, 1980, 191 (05) :539-545
[3]  
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[4]  
BEREND N, 1982, AM REV RESPIR DIS, V126, P646
[5]   INSPIRATORY PRESSURE SUPPORT PREVENTS DIAPHRAGMATIC FATIGUE DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
HARF, A ;
LORINO, H ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (02) :513-521
[6]  
COLERIDGE HM, 1986, HDB PHYSL 3, V2, P407
[7]   PRESSURE-TIME PRODUCT, FLOW, AND OXYGEN COST OF RESISTIVE BREATHING IN HUMANS [J].
COLLETT, PW ;
PERRY, C ;
ENGEL, LA .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (04) :1263-1272
[8]   STUDIES ON CONTINUOUS POSITIVE AIRWAY PRESSURE BREATHING SYSTEMS [J].
COX, D ;
NIBLETT, DJ .
BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (08) :905-911
[9]   LIMITATIONS OF MEASUREMENT OF TRANS-DIAPHRAGMATIC PRESSURE IN DETECTING DIAPHRAGMATIC WEAKNESS [J].
DETROYER, A ;
ESTENNE, M .
THORAX, 1981, 36 (03) :169-174
[10]   WEANING FROM CONTROLLED VENTILATION AND SUPPLEMENTAL OXYGEN [J].
FEELEY, TW ;
HEDLEYWHYTE, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1975, 292 (17) :903-906