ADHESION OF ENDOTHELIAL-CELLS AND ADSORPTION OF SERUM-PROTEINS ON GAS PLASMA-TREATED POLYTETRAFLUOROETHYLENE

被引:179
作者
DEKKER, A [1 ]
REITSMA, K [1 ]
BEUGELING, T [1 ]
BANTJES, A [1 ]
FEIJEN, J [1 ]
VANAKEN, WG [1 ]
机构
[1] UNIV TWENTE, FAC CHEM TECHNOL, POB 217, 7500 AE ENSCHEDE, NETHERLANDS
关键词
POLYTETRAFLUOROETHYLENE; HUMAN ENDOTHELIAL CELLS; GAS PLASMA;
D O I
10.1016/0142-9612(91)90191-C
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
From in vitro experiments it is known that human endothelial cells show poor adhesion to hydrophobic polymers. The hydrophobicity of vascular prostheses manufactured from Teflon(R) or Dacron(R) may be the reason why endothelialization of these grafts does not occur after implantation in humans. We modified films of polytetrafluoroethylene (Teflon(R)) by nitrogen plasma and oxygen plasma treatments to make the surfaces more hydrophilic. Depending on the plasma exposure time, modified polytetrafluoroethylene surfaces showed water-contact angles of 15-58-degrees, versus 96-degrees for unmodified polytetrafluoroethylene. ESCA measurements revealed incorporation of both nitrogen- and oxygen-containing groups into the polytetrafluoroethylene surfaces, dependent on the plasma composition and exposure time. The thickness of the modified surface layer was approximately 1 nm. The adhesion of cultured human endothelial cells from 20% human serum-containing culture medium to modified polytetrafluoroethylene surfaces with contact angles of 20-45-degrees led to the formation of a monolayer of cells, which was similar to the one formed on tissue culture polystyrene, the reference surface. This was not the case when endothelial cells were seeded upon unmodified polytetrafluoroethylene. Surface-modified expanded polytetrafluoroethylene prosthesis material (GORE TEX(R) soft tissue) also showed adhesion of endothelial cells comparable to cell adhesion to the reference surface. The amounts of serum proteins, including fibronectin, adsorbed from serum-containing medium to modified polytetrafluoroethylene surfaces were larger than those adsorbed to unmodified polytetrafluoroethylene. Moreover, the modified surfaces probably allow the exchange of adsorbed serum proteins with cellular fibronectin.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 39 条
  • [1] ENDOTHELIALIZATION OF POLYMER SURFACES
    ABSOLOM, DR
    HAWTHORN, LA
    CHANG, G
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (04): : 271 - 285
  • [2] INFLUENCE OF ENDOTHELIAL-CELL SEEDING ON PLATELET DEPOSITION AND PATENCY IN SMALL-DIAMETER DACRON ARTERIAL GRAFTS
    ALLEN, BT
    LONG, JA
    CLARK, RE
    SICARD, GA
    HOPKINS, KT
    WELCH, MJ
    [J]. JOURNAL OF VASCULAR SURGERY, 1984, 1 (01) : 224 - 233
  • [3] [Anonymous], 1985, SURFACE INTERFACIAL
  • [4] HEALING OF ARTERIAL PROSTHESES IN MAN - ITS INCOMPLETENESS
    BERGER, K
    WOOD, SJ
    SAUVAGE, LR
    RAO, AM
    [J]. ANNALS OF SURGERY, 1972, 175 (01) : 118 - &
  • [5] Brash J.L., 1983, BIOCOMPATIBLE POLYM, P35
  • [6] Burkel W, 1982, BIOL SYNTHETIC VASCU, P631
  • [7] CALLOW AD, 1982, BIOL SYNTHETIC VASCU, P11
  • [8] CHILKOTI A, 1989, 15TH T ANN M SOC BIO, V12, P99
  • [9] ENHANCEMENT OF SERUM FIBRONECTIN ADSORPTION AND THE CLONAL PLATING EFFICIENCIES OF SWISS MOUSE-3T3 FIBROBLAST AND MM14-MOUSE MYOBLAST CELLS ON POLYMER SUBSTRATES MODIFIED BY RADIOFREQUENCY PLASMA DEPOSITION
    CHINN, JA
    HORBETT, TA
    RATNER, BD
    SCHWAY, MB
    HAQUE, Y
    HAUSCHKA, SD
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1989, 127 (01) : 67 - 87
  • [10] DEKKER A, 1989, THROMB HAEMOSTASIS, V61, P402