AN ACCURATE METHOD FOR DIRECT DUAL-ENERGY CALIBRATION AND DECOMPOSITION

被引:123
作者
CARDINAL, HN [1 ]
FENSTER, A [1 ]
机构
[1] JOHN P ROBARTS RES INST,IMAGING RES LABS,LONDON N6A 5K8,ONTARIO,CANADA
关键词
digital radiography; dual energy; least squares; noise; quantitative imaging;
D O I
10.1118/1.596512
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We propose the use of conic and cubic surface equations (surfaces of second and third order) to directly approximate the dual-energy equations (the integral equations for the dual-energy log-signal functions, i.e., the negative logarithms of the relative detector signals, considered as functions of the basis-material component thicknesses of the object) and especially their inverses. These types of surface equations require a minimum number of calibration points, and their solutions are smooth, monotonic functions with the correct linear asymptotic behavior. The accuracy of this method is investigated and compared to that of conventional polynomial approximations, both for simulated and real calibration data, taken from two split-detector systems. These systems provide a more stringent test of our method than comparable dual-kVp systems, due to the greater nonlinearity of their log-signal and inverse functions. For these systems, we show that direct approximation of the inverse dual-energy equations using the simple eight-term rational form of the conic surface equation provides an extremely fast decomposition algorithm, which is accurate, robust in the presence of noise, and which can be calibrated with as few as 9 calibration points, or robustly calibrated, with a built-in accuracy check, using only 16 calibration points. Also, we show that extreme accuracy of approximation (to within less than 10-6 in log-signal and 1 μm in material thickness) is theoretically attainable using the eighteen-term form of the cubic surface equation, which has a closed-form analytic solution. Finally, we consider the effects of noise on calibration accuracy, and derive simple formulas which relate the true and apparent root-mean-square (rms) accuracies. These formulas then allow the comparison of the true rms calibration accuracies of various surface approximations, considered as functions of the total calibration heat loading of the x-ray tube. © 1990, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:327 / 341
页数:15
相关论文
共 44 条
[1]   COMPARISON OF NOISE AND DOSE IN CONVENTIONAL AND ENERGY SELECTIVE COMPUTED-TOMOGRAPHY [J].
ALVAREZ, R ;
SEPPI, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2853-2855
[2]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[3]   RADIOGRAPHIC SCREENING FOR BREAST-CARCINOMA .3. APPEARANCE OF CARCINOMA AND NUMBER OF PROJECTIONS TO BE USED AT SCREENING [J].
ANDERSSON, I .
ACTA RADIOLOGICA-DIAGNOSIS, 1981, 22 (04) :407-420
[4]   BREAST IMAGING - DUAL-ENERGY PROJECTION RADIOGRAPHY WITH DIGITAL RADIOGRAPHY [J].
ASAGA, T ;
CHIYASU, S ;
MASTUDA, S ;
MASTUURA, H ;
KATO, H ;
ISHIDA, M ;
KOMAKI, T .
RADIOLOGY, 1987, 164 (03) :869-870
[5]   DETECTOR FOR DUAL-ENERGY DIGITAL RADIOGRAPHY [J].
BARNES, GT ;
SONES, RA ;
TESIC, MM ;
MORGAN, DR ;
SANDERS, JN .
RADIOLOGY, 1985, 156 (02) :537-540
[6]  
BEVINGTON PR, 1977, DATA REDUCTION ERROR, P66
[7]  
BIRCH R, 1979, CATALOGUE SPECTRAL D, P24
[8]   HYBRID SUBTRACTION FOR IMPROVED ARTERIOGRAPHY [J].
BRODY, WR .
RADIOLOGY, 1981, 141 (03) :828-831
[9]   A METHOD FOR SELECTIVE TISSUE AND BONE VISUALIZATION USING DUAL ENERGY SCANNED PROJECTION RADIOGRAPHY [J].
BRODY, WR ;
BUTT, G ;
HALL, A ;
MACOVSKI, A .
MEDICAL PHYSICS, 1981, 8 (03) :353-357
[10]   DUAL-ENERGY PROJECTION RADIOGRAPHY - INITIAL CLINICAL-EXPERIENCE [J].
BRODY, WR ;
CASSEL, DM ;
SOMMER, FG ;
LEHMANN, LA ;
MACOVSKI, A ;
ALVAREZ, RE ;
PELC, NJ ;
RIEDERER, SJ ;
HALL, AL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) :201-205