THE CALIBRATION OF A LOW-ENERGY PHOTON GERMANIUM DETECTOR FOR USE IN THE NAA K0 STANDARDIZATION METHOD

被引:11
作者
DECORTE, F [1 ]
FREITAS, MC [1 ]
DEWISPELAERE, A [1 ]
机构
[1] LAB NACL ENGN & TECHNOL IND,DEPT ENERGIA & ENGN NUCL,P-2685 SACAVEM,PORTUGAL
关键词
D O I
10.1016/0168-9002(90)90802-D
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To extend the NAA k0 method to LEPD counting, procedures were elaborated for determining the full-energy peak detection efficiency epsilon-p and the peak-to-total ratio P/T (yielding the total efficiency epsilon-t = epsilon-p/(P/T). epsilon-p is needed for concentration calculation. epsilon-p and epsilon-t are needed to correct for true coincidences (including KX and LX lines) in case of small source-detector separation. First the "reference" efficiency curve (log-epsilon-p,ref vs log E) was determined with calibrated point sources (from 4.65 keV (Ce-139) to 383.9 keV (Ba-133)) measured at approximately 16 cm distance from the LEPD. The accuracy is approximately 1-2% for E > 11 keV, and approximately 5% for E < 11 keV. In view of actual analyses, epsilon-p,ref was converted to epsilon-p,geo (i.e. at a small distance from the LEPD) based on the calculation of the effective solid angles OMEGABAR with the program SOLANG. The accuracy of this, checked with practically coincidence-free lines of point sources measured close to the LEPD, was approximately 5% on the average. After identifying the origin of all the pulses in the spectra, a P/T curve (log P/T vs log E) was constructed from results obtained for the most prominent lines of some nine sources (from 5.9 keV (55-Fe) to 320.1 keV (Cr-51)). P/T was found to be practically independent of the source-detector separation. Its accuracy of approximately 5% is satisfactory in view of the large error reduction. The results and conclusions reached here were obtained from experiments with two different LEPDs at the INW, Gent and the LNETI, Sacavem.
引用
收藏
页码:335 / 343
页数:9
相关论文
共 5 条
[1]  
DEBEECK JO, UNPUB
[2]   ACCURACY AND APPLICABILITY OF THE K0-STANDARDIZATION METHOD [J].
DECORTE, F ;
SIMONITS, A ;
DEWISPELAERE, A ;
HOSTE, J .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1987, 113 (01) :145-161
[3]   ACCURATE EFFICIENCY CALIBRATION AND PROPERTIES OF SEMICONDUCTOR DETECTORS FOR LOW-ENERGY PHOTONS [J].
HANSEN, JS ;
MCGEORGE, JC ;
NIX, D ;
SCHMIDTO.WD ;
UNUS, I ;
FINK, RW .
NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (02) :365-379
[4]   CALCULATION OF THE ABSOLUTE PEAK EFFICIENCY OF GAMMA-RAY DETECTORS FOR DIFFERENT COUNTING GEOMETRIES [J].
MOENS, L ;
DEDONDER, J ;
LIN, X ;
DECORTE, F ;
DEWISPELAERE, A ;
SIMONITS, A ;
HOSTE, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 187 (2-3) :451-472
[5]   CALCULATION OF THE PEAK EFFICIENCY OF HIGH-PURITY GERMANIUM DETECTORS [J].
MOENS, L ;
HOSTE, J .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08) :1085-1095