OPTIMIZATION OF METAL/PHOSPHOR SCREENS FOR ONLINE PORTAL IMAGING

被引:25
作者
WOWK, B
RADCLIFFE, T
LESZCZYNSKI, KW
SHALEV, S
RAJAPAKSHE, R
机构
[1] QUEENS UNIV,DEPT PHYS,KINGSTON K7L 3N6,ON,CANADA
[2] NE ONTARIO REG CANC CTR,SUDBURY P3E 5J1,ON,CANADA
[3] UNIV MANITOBA,DEPT PHYS,WINNIPEG R3T 2N2,MB,CANADA
[4] UNIV MANITOBA,DEPT RADIOL,WINNIPEG,MB,CANADA
关键词
ONLINE PORTAL IMAGING; FLUORESCENT SCREENS; PHOSPHORS; OPTIMIZATION;
D O I
10.1118/1.597299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Studies were conducted to determine the optimal metal/phosphor screen for on-line video verification of radiation treatment portals. Screens were evaluated for luminance and spatial resolution as a function of composition and thickness at 6- and 23-MV x-ray energies. A new video technique was used to determine modulation transfer functions. Gd2O2S was found to be the most efficient (brightest), phosphor for this application. Luminance was found to vary linearly with phosphor thickness up to a thickness of 500 mg/cm(2). Metal plates made of iron, brass, copper, lead, and sintered tungsten of various thicknesses were also tested for luminance and resolution with Gd2O2S phosphor. Brightness peaked at about 2-mm thickness for most metals. Significant contributions to the brightness were found to come from x rays interacting with the phosphor itself.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 23 条
[1]   USE OF STORAGE PHOSPHOR IMAGING PLATES IN PORTAL IMAGING AND HIGH-ENERGY RADIOGRAPHY - THE INTENSIFYING EFFECT OF METALLIC SCREENS ON THE SENSITIVITY [J].
BARNEA, G ;
NAVON, E ;
GINZBURG, A ;
POLITCH, J ;
ROEHRIG, H ;
DICK, CE ;
PLACIOUS, RC .
MEDICAL PHYSICS, 1991, 18 (03) :432-438
[2]   HIGH-ENERGY X-RAY-FILM RESPONSE AND THE INTENSIFYING ACTION OF METAL SCREENS [J].
BARNEA, G ;
GINZBURG, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (06) :1580-1585
[3]   CHARACTERIZATION OF FLUORESCENT SCREENS FOR IMAGING APPLICATIONS WITH MEV NEUTRONS AND PHOTONS [J].
BERZINS, GJ ;
LUMPKIN, AH ;
SMITH, HL .
OPTICAL ENGINEERING, 1983, 22 (05) :633-642
[4]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[5]   METAL-PHOSPHOR INTENSIFYING SCREENS FOR HIGH-ENERGY IMAGING APPLICATIONS [J].
BUCHANAN, RA ;
SKLENSKY, AF ;
MAPLE, TG ;
BAILEY, HN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) :692-694
[6]  
CURRY TS, 1990, CHRISTENSENS PHYSICS, P124
[7]  
Droege R T, 1979, Med Phys, V6, P272, DOI 10.1118/1.594581
[8]  
DROEGE R T, 1979, Medical Physics (Woodbury), V6, P515, DOI 10.1118/1.594615
[9]  
FANO U, 1954, RADIAT RES, V1, P27
[10]   ABSOLUTE EFFICIENCY OF GD2O2S - TB SCREENS UNDER FLUOROSCOPIC CONDITIONS [J].
GIAKOUMAKIS, GE ;
NOMICOS, CD ;
SANDILOS, PX .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :673-678