USE OF DIGITAL FRONT-END ELECTRONICS FOR OPTIMIZATION OF A MODULAR PET DETECTOR

被引:11
作者
CUTLER, PD [1 ]
HOFFMAN, EJ [1 ]
机构
[1] UNIV CALIF LOS ANGELES, DIV NUCL MED & BIOPHYS, LOS ANGELES, CA USA
关键词
D O I
10.1109/42.293933
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The sensitivity and resolution of a new 2-D modular BGO detector system for PET was examined in terms of its effect on the signal to noise ratio in the final image. The detector system uses custom hardware and firmware to adjust sensitivity and resolution to achieve optimum performance. This system utilizes lookup up tables (LUT) containing individually tailored positioning and energy windows to assure that events are correctly distributed among the detector elements. Without customizing the LUT, and for a common energy window, sensitivity was found to vary as much as a factor of 3.5 and resolution as much as 50% from center to edge within a single detector module. Eight different LUT configurations were tested, varying both energy window and positioning criteria. Typical intrinsic resolutions and sensitivities of the detector elements were determined in all configurations. The effect of nonuniformity of sensitivity of the detector system on image noise was evaluated by imaging uniform cylinders over a wide range of accumulated events. The effect of counting statistics in the measurement of detector sensitivities for the normalization of sinogram data was determined independently. The best of the LUT configurations provided an 16% improvement in effective sensitivity, while also providing a 10% improvement in the average intrinsic spatial resolution relative to the default configuration of the PET system.
引用
收藏
页码:408 / 418
页数:11
相关论文
共 9 条
  • [1] EMISSION COMPUTER-ASSISTED TOMOGRAPHY WITH SINGLE-PHOTON AND POSITRON-ANNIHILATION PHOTON EMITTERS
    BUDINGER, TF
    DERENZO, SE
    GULLBERG, GT
    GREENBERG, WL
    HUESMAN, RH
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) : 131 - 145
  • [2] A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY
    CASEY, ME
    NUTT, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 460 - 463
  • [3] CUTLER PD, 1992, J NUCL MED, V33, P595
  • [4] AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET
    DAHLBOM, M
    HOFFMAN, EJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) : 264 - 272
  • [5] INITIAL CHARACTERIZATION OF A POSITION-SENSITIVE PHOTODIODE BGO DETECTOR FOR PET
    DERENZO, SE
    MOSES, WW
    JACKSON, HG
    TURKO, BT
    CAHOON, JL
    GEYER, AB
    VULETICH, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1084 - 1089
  • [6] PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES
    HOFFMAN, EJ
    GUERRERO, TM
    GERMANO, G
    DIGBY, WM
    DAHLBOM, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1108 - 1112
  • [7] MOYER JC, 1990, THESIS U TENNESSEE K
  • [8] AN ANALYSIS OF SIGNAL AMPLIFICATION USING SMALL DETECTORS IN POSITRON EMISSION TOMOGRAPHY
    PHELPS, ME
    HUANG, SC
    HOFFMAN, EJ
    PLUMMER, D
    CARSON, R
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (03) : 551 - 565
  • [9] [No title captured]