CARBON-DIOXIDE, TEMPERATURE AND LAPAROSCOPIC CHOLECYSTECTOMY

被引:14
作者
MONAGLE, J
BRADFIELD, S
NOTTLE, P
机构
[1] Department of Anaesthesia, Alfred Hospital, Melbourne, Victoria
来源
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY | 1993年 / 63卷 / 03期
关键词
ANESTHESIA; CARBON DIOXIDE; LAPAROSCOPIC; TEMPERATURE;
D O I
10.1111/j.1445-2197.1993.tb00515.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Laparoscopic procedures have previously been shown to interfere little with respiratory homeostasis. This study was designed to determine whether respiratory homeostasis, as well as temperature, is maintained with longer laparoscopic procedures and cold carbon dioxide insufflation. This study examined 21 American Society of Anesthesiologists status I and II patients undergoing laparoscopic cholecystectomy. A constant minute ventilation (80 mL/kg per min) was instituted prior to peritoneal insufflation and end-tidal carbon dioxide measurements were followed throughout the procedure. Although they showed a small statistically significant increase (32.3 +/- 3.8 to 38.9 +/- 6.0 mmHg, P = 0.0001) they were not of clinical significance. Similarly, rectal temperature measurements showed a statistically, but not clinically, significant fall in temperature over the course of the procedures (36.4 +/- 0.46 to 36.2 +/- 0.35-degrees-C, P = 0.000 1). The changes in end-tidal carbon dioxide and temperature showed no correlation with the volume of carbon dioxide used. The above findings will, however, require further investigation in both longer procedures and patients with more significant disease.
引用
收藏
页码:186 / 189
页数:4
相关论文
共 12 条
[1]  
BERNE RM, 1983, PHYSIOLOGY
[2]  
BRAMPTON WJ, 1990, ANAESTHESIA, V45, P2210
[3]  
Damask M. C., 1983, Clinics in Anaesthesiology, V1, P599
[4]   SOME EFFECTS OF PERITONEAL INSUFFLATION OF CARBON DIOXIDE AT LAPAROSCOPY [J].
HODGSON, C ;
MCCLELLAND, RM ;
NEWTON, JR .
ANAESTHESIA, 1970, 25 (03) :382-+
[5]   HEAT LOSS DURING ANESTHESIA [J].
HOLDCROFT, A ;
HALL, GM .
BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (02) :157-164
[6]   BODY-TEMPERATURE AND ANESTHESIA [J].
IMRIE, MM ;
HALL, GM .
BRITISH JOURNAL OF ANAESTHESIA, 1990, 64 (03) :346-354
[7]   CARDIAC-OUTPUT AND ARTERIAL BLOOD-GAS TENSION DURING LAPAROSCOPY [J].
KELMAN, GR ;
SWAPP, GH ;
SMITH, I ;
BENZIE, RJ ;
GORDON, NLM .
BRITISH JOURNAL OF ANAESTHESIA, 1972, 44 (11) :1155-1162
[8]  
MOTEW M, 1973, AM J OBSTET GYNECOL, V115, P1007
[9]  
NUNN JF, 1977, APPLIED RESPIRATORY
[10]   CARBON DIOXIDE HOMEOSTASIS DURING ANAESTHESIA FOR LAPAROSCOPY [J].
SEED, RF ;
SHAKESPEARE, TF ;
MULDOON, MJ .
ANAESTHESIA, 1970, 25 (02) :223-+