A SIMPLE METHOD TO ESTIMATE FUNCTIONAL RESIDUAL CAPACITY IN MECHANICALLY VENTILATED PATIENTS

被引:27
作者
FRETSCHNER, R [1 ]
DEUSCH, H [1 ]
WEITNAUER, A [1 ]
BRUNNER, JX [1 ]
机构
[1] HAMILTON BONADUZ AG,SCI RES ABT,BONADUZ,SWITZERLAND
关键词
MECHANICAL VENTILATION; RESPIRATION; FUNCTIONAL RESIDUAL CAPACITY; LUNG VOLUME;
D O I
10.1007/BF01724875
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The aim of the present study was to evaluate a simplified method for FRC measurement. Design: Accuracy and precision of the method were assessed in a physical lung model; reproducibility was tested in 10 mechanically ventilated patients. In each patient FRC was measured at three PEEP levels. Setting: Post-operative intensive care unit in a university hospital. Measurements and results: Gas flow, CO2 concentration, and O2 concentration were measured during in- and expiration by pneumotachography, a mainstream capnometer and a sidestream O2-analyser. For FRC-measurement inspiratory O2 concentration was changed by 30%. FRC was determined as mean value of a N2 washout and N2 washin procedure. Evaluation of this method in a lung model shows a good correlation between FRC set in the lung model and FRC measured (FRC measured = 1.028*FRC model + 22.92 ml; r2 = 0.957; n = 30). The mean difference was 4.4% of FRC-reference (range - 8.4% to + 21.7%). Duplicate determinations in 10 mechanically ventilated patients differed by an average of -2.7% (range -30.1% to +27.3%). Conclusion: Our results suggest that the proposed method can be used in daily clinical work.
引用
收藏
页码:372 / 376
页数:5
相关论文
共 14 条
[1]   THE RESPIRATORY DEAD SPACE MEASURED BY SINGLE BREATH ANALYSIS OF OXYGEN, CARBON DIOXIDE, NITROGEN OR HELIUM [J].
BARTELS, J ;
SEVERINGHAUS, JW ;
FORSTER, RE ;
BRISCOE, WA ;
BATES, DV .
JOURNAL OF CLINICAL INVESTIGATION, 1954, 33 (01) :41-48
[2]   DISTRIBUTION OF INSPIRED GAS DURING ANESTHESIA AND ARTIFICIAL VENTILATION [J].
BERGMAN, NA .
JOURNAL OF APPLIED PHYSIOLOGY, 1963, 18 (06) :1085-+
[3]   ACCURATE MEASUREMENT OF N-2 VOLUMES DURING N-2 WASHOUT REQUIRES DYNAMIC ADJUSTMENT OF DELAY TIME [J].
BRUNNER, JX ;
WOLFF, G ;
CUMMING, G ;
LANGENSTEIN, H .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (03) :1008-1012
[4]   HOW THE RISE TIME OF CARBON-DIOXIDE ANALYZERS INFLUENCES THE ACCURACY OF CARBON-DIOXIDE MEASUREMENTS [J].
BRUNNER, JX ;
WESTENSKOW, DR .
BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (05) :628-638
[5]  
Brunner JX, 1988, PHYS MODEL LUNG PULM, P58
[6]  
BRUNNER JX, 1988, PULMONARY FUNCTION I, P100
[7]  
CONNORS AF, 1981, AM REV RESPIR DIS, V124, P537
[8]  
FELTON CR, 1984, INTENS CARE MED, V10, P281
[9]   MEASUREMENT OF FUNCTIONAL RESIDUAL CAPACITY BY SULFUR-HEXAFLUORIDE WASHOUT [J].
JONMARKER, C ;
JANSSON, L ;
JONSON, B ;
LARSSON, A ;
WERNER, O .
ANESTHESIOLOGY, 1985, 63 (01) :89-95
[10]   TIME COURSE AND MECHANISMS OF LUNG-VOLUME INCREASE WITH PEEP IN ACUTE PULMONARY FAILURE [J].
KATZ, JA ;
OZANNE, GM ;
ZINN, SE ;
FAIRLEY, HB .
ANESTHESIOLOGY, 1981, 54 (01) :9-16