A MULTIPARAMETER OPTIMIZATION OF DIGITAL MAMMOGRAPHY

被引:8
作者
COURT, LE [1 ]
SPELLER, R [1 ]
机构
[1] UCL, DEPT MED PHYS, LONDON WC1E 6JA, ENGLAND
关键词
D O I
10.1088/0031-9155/40/11/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multiparameter optimizations have been carried out for a wide range of digital mammography system configurations and requirements, with the aim of optimizing the image quality for a given patient dose. These conditions include a range of slot widths for scanning mammography systems, exposure times from 1 to 10 s, focal spot sizes from 80 to 800 mu m, a range of detector resolutions and noise levels, dose restrictions, patient thicknesses and targets, and x-ray tube targets. The influences of these on the optimum system configuration in terms of tube potential, filtration, source to patient distance and target magnification are discussed. It is demonstrated that x-ray tube power constraints can significantly restrict the optimum magnification for slot scanning systems, with the result that poor-resolution detectors are not suited for use in a scanning configuration, and that large-focal-spot-good-detector resolution combinations are more suitable. The use of a detector with increased width, raised tube potential and reduced amount of added filtration is shown to be helpful in reducing x-ray tube power limitations. It is shown that, in many cases, correct optimization can bring the detail SNR for an examination using a given detector-x-ray tube configuration to within 10-15% of the SNR achieved with the optimum combination. This gives the designer some scope to consider other factors such as cost and the implications of image size on storage space.
引用
收藏
页码:1841 / 1861
页数:21
相关论文
共 23 条
[1]  
[Anonymous], [No title captured]
[2]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[3]  
COURT LE, 1994, P SOC PHOTO-OPT INS, V2163, P298, DOI 10.1117/12.174267
[4]   A SPATIAL-FREQUENCY DEPENDENT QUANTUM ACCOUNTING DIAGRAM AND DETECTIVE QUANTUM EFFICIENCY MODEL OF SIGNAL AND NOISE-PROPAGATION IN CASCADED IMAGING-SYSTEMS [J].
CUNNINGHAM, IA ;
WESTMORE, MS ;
FENSTER, A .
MEDICAL PHYSICS, 1994, 21 (03) :417-427
[5]  
CUNNINGHAM IA, 1994, P SOC PHOTO-OPT INS, V2163, P274, DOI 10.1117/12.174264
[7]  
FAHRIG R, 1992, P SOC PHOTO-OPT INS, V1651, P74, DOI 10.1117/12.59405
[8]   TECHNOLOGIC IMPROVEMENTS IN SCREEN-FILM MAMMOGRAPHY [J].
HAUS, AG .
RADIOLOGY, 1990, 174 (03) :628-637
[9]   OPTIMAL X-RAY-SPECTRA FOR SCREEN-FILM MAMMOGRAPHY [J].
JENNINGS, RJ ;
EASTGATE, RJ ;
SIEDBAND, MP ;
ERGUN, DL .
MEDICAL PHYSICS, 1981, 8 (05) :629-639
[10]   X-RAY CHARACTERIZATION OF NORMAL AND NEOPLASTIC BREAST TISSUES [J].
JOHNS, PC ;
YAFFE, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (06) :675-695