SIGNAL AMPLIFICATION FOR HIGH CAPACITANCE IONIZATION CHAMBERS

被引:5
作者
CENTRO, S [1 ]
机构
[1] IST NAZL FIS NUCL,PADUA,ITALY
关键词
D O I
10.1016/0168-9002(92)90736-N
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The general problem of high capacitance detectors is discussed from the point of view of high charge sensitivity obtained by paralleling many input j-fets.
引用
收藏
页码:404 / 410
页数:7
相关论文
共 11 条
[1]   PERFORMANCE OF A URANIUM TETRAMETHYLPENTANE ELECTROMAGNETIC CALORIMETER [J].
ALBROW, MG ;
APSIMON, R ;
AUBERT, B ;
BACCI, C ;
BEZAGUET, A ;
BONINO, R ;
CENNINI, P ;
CENTRO, S ;
CERADINI, F ;
COCHET, C ;
COLAS, J ;
CONTE, R ;
DEBRION, JP ;
DEGIORGI, M ;
DICIACCIO, A ;
DIEZHEDO, F ;
DOWELL, JD ;
DUMPS, L ;
GHEZ, P ;
GIVERNAUD, A ;
GONIDEC, A ;
KIENZLE, W ;
LACAVA, F ;
LOOTEN, A ;
MARKIEWICZ, T ;
MARKOU, C ;
MAURIN, G ;
MENEGUZZO, A ;
MULLER, T ;
MUNOZ, R ;
NAUMANN, L ;
OCHSENBEIN, S ;
PETROLO, E ;
PIGOT, C ;
PLACCI, A ;
PRIPSTEIN, M ;
RADERMACHER, E ;
ROBINSON, D ;
RUBBIA, C ;
SASS, J ;
SCHINZEL, D ;
SCHMIDT, WF ;
SEEZ, C ;
SEIDL, W ;
STREETS, J ;
SUMOROK, K ;
VENEZIANO, S ;
VIRDEE, TS ;
WARMUTH, E ;
ZANELLO, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 265 (1-2) :303-318
[2]  
BACCI C, 1989, NUCL INSTRUM METH A, V279, P169
[3]   A HYBRID CHARGE SENSITIVE AMPLIFIER FOR HIGH CAPACITANCE DETECTORS [J].
BACCI, C ;
CENTRO, S ;
DEGIORGI, M ;
MARTINELLI, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01) :321-325
[4]   PERSPECTIVES IN THE DESIGN OF TRANSFORMERLESS, LOW-NOISE FRONT-END ELECTRONICS FOR LARGE CAPACITANCE DETECTORS AND CALORIMETERS IN ELEMENTARY PARTICLE PHYSICS [J].
BERTOLACCINI, M ;
PADOVINI, G ;
CAMIN, DV ;
MANFREDI, PF ;
PRESTON, JA ;
REHN, LA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 264 (2-3) :399-406
[5]  
BRASSARD C, 1979, NUCL INSTRUM METHODS, V126, P29
[6]   LOW-NOISE, TRANSFORMERLESS FRONT-END ELECTRONICS FOR MODERATE AND HIGH CAPACITANCE CALORIMETERS [J].
CAMIN, DV ;
CATTADORI, C ;
LATORRE, S ;
RAGUSA, F ;
RANUCCI, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 279 (1-2) :195-203
[7]  
DOKE T, 1985, NUCL INSTRUM METH A, V273, P475
[8]  
GATTI G, 1985, NUOVO CIMENTO, V9, P1
[9]  
RADEKA V, 1973, CALORIMETER NOTES
[10]   LIQUID-ARGON IONIZATION CHAMBERS AS TOTAL-ABSORPTION DETECTORS [J].
WILLIS, WJ ;
RADEKA, V .
NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (02) :221-236