COLOR DOPPLER IMAGING OF ORBITAL ARTERIES FOR DETECTION OF CAROTID OCCLUSIVE DISEASE

被引:56
作者
HU, HH
SHENG, WY
YEN, MY
LAI, ST
TENG, MMH
机构
[1] TAIPEI VET GEN HOSP, YANG MING MED COLL, DEPT OPHTHALMOL, TAIPEI, TAIWAN
[2] TAIPEI VET GEN HOSP, YANG MING MED COLL, DEPT SURG, TAIPEI, TAIWAN
[3] TAIPEI VET GEN HOSP, YANG MING MED COLL, DEPT RADIOL, TAIPEI 11217, TAIWAN
关键词
CAROTID ARTERY DISEASES; OPHTHALMIC ARTERY; RETINAL ARTERY; ULTRASONICS;
D O I
10.1161/01.STR.24.8.1196
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose: Distal to a hemodynamically significant stenosis, the Doppler effect becomes dampened. Thus, measuring the flow profile in the ophthalmic artery and the central retinal artery with color Doppler imaging may provide hemodynamic information about the carotid circulation. Methods: To validate the flow profile measurement with color Doppler imaging in the ophthalmic and central retinal arteries and to determine the sensitivity and specificity of this examination in the detection of hemodynamically significant carotid stenosis, we compared color Doppler imaging examinations with ocular pneumoplethysmography and ophthalmodynamometry examinations in 66 patients with atherothrombotic ischemic cerebrovascular disease. The degree of carotid stenosis in these patients was determined by a duplex scan with color Doppler imaging, and 57 patients underwent angiography to verify the stenosis. Results: The flow velocities (systolic peak velocity and end-diastolic velocity) and pulsatility indices (A/B ratio and resistance index) in the ophthalmic and central retinal arteries decreased as the degree of carotid stenosis increased. There is a statistically significant difference in the mean of systolic peak velocity and the mean of end-diastolic velocity of the ophthalmic and central retinal arteries among groups with various degrees of carotid stenosis (P<.02). Using the flow velocities of the ophthalmic and central retinal arteries to diagnose carotid stenosis (greater-than-or-equal-to 75% stenosis and occlusion), 8 cm/s for systolic peak velocity in the central retinal artery and 29 cm/s for systolic peak velocity plus flow direction reversal in the ophthalmic artery gave the maximum accuracy (sensitivities, 84% and 85.7% and specificities, 89.6% and 81.7%, respectively). The systolic peak velocity in the central retinal artery varied directly with the systolic pressure of the ophthalmic and central retinal arteries. Conclusions: The How velocity and pulsatility in orbital arteries examined by color Doppler imaging provide further hemodynamic information; this test can be used to complement current sonographic examination of carotid disease.
引用
收藏
页码:1196 / 1203
页数:8
相关论文
共 37 条
[1]   SYMPTOMATIC CAROTID-ARTERY STENOSIS - A SOLVABLE PROBLEM - NORTH-AMERICAN SYMPTOMATIC CAROTID ENDARTERECTOMY TRIAL [J].
BARNETT, HJM ;
BARNES, RW ;
CLAGETT, GP ;
FERGUSON, GG ;
ROBERTSON, JT ;
WALKER, PM .
STROKE, 1992, 23 (08) :1048-1053
[2]   STUMP OF INTERNAL CAROTID-ARTERY - SOURCE FOR FURTHER CEREBRAL EMBOLIC ISCHEMIA [J].
BARNETT, HJM ;
PEERLESS, SJ ;
KAUFMANN, JCE .
STROKE, 1978, 9 (05) :448-456
[3]  
BATKO KA, 1979, ANN OPHTHALMOL, V11, P1499
[4]  
BELKIN M, 1985, ARCH SURG-CHICAGO, V120, P809
[5]  
Bluth E I, 1988, Radiographics, V8, P487
[6]   EXTERNAL CAROTID-ARTERY IN INTERNAL CAROTID-ARTERY OCCLUSION - ANGIOGRAPHIC, THERAPEUTIC, AND PROGNOSTIC CONSIDERATIONS [J].
COUNTEE, RW ;
VIJAYANATHAN, T .
STROKE, 1979, 10 (04) :450-460
[7]  
EIKELBOOM B, 1983, ARCH SURG-CHICAGO, V118, P1169
[8]   COLOR DOPPLER FLOW IMAGING OF THE NORMAL AND ABNORMAL ORBIT [J].
ERICKSON, SJ ;
HENDRIX, LE ;
MASSARO, BM ;
HARRIS, GJ ;
LEWANDOWSKI, MF ;
FOLEY, WD ;
LAWSON, TL .
RADIOLOGY, 1989, 173 (02) :511-516
[9]   ULTRASONIC DUPLEX SCANNING FOR DISEASE OF THE CAROTID-ARTERY [J].
FELL, G ;
PHILLIPS, DJ ;
CHIKOS, PM ;
HARLEY, JD ;
THIELE, BL ;
STRANDNESS, DE .
CIRCULATION, 1981, 64 (06) :1191-1195
[10]   CAROTID PHYSIOLOGY WITH OCULAR PNEUMOPLETHYSMOGRAPHY [J].
GEE, W .
STROKE, 1982, 13 (05) :666-673