EFFECTS OF ORIFICE SIZE AND SURFACE CONDITIONS ON OXYGEN-TRANSFER IN A BENCH SCALE DIFFUSED AERATION SYSTEM

被引:7
作者
ASHLEY, KI [1 ]
MAVINIC, DS [1 ]
HALL, KJ [1 ]
机构
[1] UNIV BRITISH COLUMBIA,DEPT CIVIL ENGN,ENVIRONM ENGN GRP,VANCOUVER V6T 1W5,BC,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1080/09593339009384903
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Non‐steady state gas transfer methodology was used to examine the effect of orifice size and surface conditions on the rate of oxygen transfer in a 239 L bench scale tank. Each orifice size tested (40 μ, 397 μ and 1588 μ) increased the overall oxygen transfer coefficient (KLa20, hr−1) ; standard oxygen transfer rate (OTs, g O2/hr) ; transfer efficiency (Eo, %) and energy efficiency (Ep/ g O2/kW‐hr) as orifice diameter decreased. The three surface conditions examined exerted a minor effect on oxygen transfer. © 1990 Publications Division Selper Ltd.
引用
收藏
页码:609 / 618
页数:10
相关论文
共 26 条
[1]  
ASHLEY KI, 1990, IN PRESS VERH INT VE, V24
[2]  
ASHLEY KI, 1989, THESIS U BC VANCOUVE
[3]   MECHANICAL MIXING AND SURFACE REAERATION [J].
BANKS, RB ;
RASCHIDSALLY, L ;
POLPRASERT, C .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1983, 109 (01) :232-241
[4]  
Barnhart E.L., 1969, J SANIT ENG DIV AM S, V95, P645
[5]  
BEWTRA JK, 1964, J WATER POLLUT CON F, V36, P1195
[6]  
Bowers R. H., 1955, J APPL CHEM-USSR, V5, P542
[7]  
BOYD CE, 1986, PROG FISH CULT, V48, P68, DOI 10.1577/1548-8640(1986)48<68:AMFTAF>2.0.CO
[8]  
2
[9]  
Clark J.W., 1977, WATER SUPPLY POLLUTI, V3rd
[10]  
Downing AL, 1955, J APPL CHEM-USSR, V5, P570, DOI DOI 10.1002/JCTB.5010051008JACHAU0021-8871