A STUDY OF THE RADIATION ENVIRONMENT ON BOARD THE SPACE-SHUTTLE FLIGHT STS-57

被引:34
作者
BADHWAR, GD
ATWELL, W
BENTON, EV
FRANK, AL
KEEGAN, RP
DUDKIN, VE
KARPOV, ON
POTAPOV, YV
AKOPOVA, AB
MAGRADZE, NV
MELKUMYAN, LV
RSHTUNI, SB
机构
[1] ROCKWELL INT CORP,DIV SPACE SYST,HOUSTON,TX 77058
[2] UNIV SAN FRANCISCO,DEPT PHYS,SAN FRANCISCO,CA 94117
[3] RES CTR SPACECRAFT RADIAT SAFETY,MOSCOW 123182,RUSSIA
[4] YEREVAN PHYS INST,YEREVAN 375036,ARMENIA
基金
美国国家航空航天局;
关键词
D O I
10.1016/1350-4487(95)00007-2
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on Space Shuttle flight STS-57 was conducted. The Shuttle flew in a nearly circular orbit of 28.5 degrees inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTDs) and thermoluminescent detectors (TLDs), and Russian nuclear emulsions, PNTDs and TLDs. All the detector systems were shielded by the same Shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/mu m and 200 keV/mu m. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than the TLDs, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLDs to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 22 条
[1]  
AKOPOVA AB, 1987, RADIAT PROT DOSIM, V18, P153
[2]   LINEAR ENERGY-TRANSFER (LET) SPECTRA OF COSMIC-RADIATION IN LOW EARTH ORBIT [J].
AKOPOVA, AB ;
MAGRADZE, NV ;
DUDKIN, VE ;
KOVALEV, EE ;
POTAPOV, YV ;
BENTON, EV ;
FRANK, AL ;
BENTON, ER ;
PARNELL, TA ;
WATTS, JW .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1990, 17 (02) :93-97
[3]  
AKOPOVA AB, 1985, KOSM ISSLED, V23, P479
[4]  
ARMSTRONG TW, 1992, NUCL TRACKS RAD MEAS, V20, P101
[5]   MEASUREMENTS ON THE SHUTTLE OF THE LET SPECTRA OF GALACTIC COSMIC-RADIATION AND COMPARISON WITH THE RADIATION TRANSPORT MODEL [J].
BADHWAR, GD ;
CUCINOTTA, FA ;
BRABY, LA ;
KONRADI, A .
RADIATION RESEARCH, 1994, 139 (03) :344-351
[6]   MEASUREMENTS OF THE SECONDARY PARTICLE ENERGY-SPECTRA IN THE SPACE-SHUTTLE [J].
BADHWAR, GD ;
PATEL, JU ;
CUCINOTTA, FA ;
WILSON, JW .
RADIATION MEASUREMENTS, 1995, 24 (02) :129-138
[7]   ACTIVE DOSIMETRIC MEASUREMENTS ON SHUTTLE FLIGHTS [J].
BADHWAR, GD ;
KONRADI, A ;
HARDY, A ;
BRABY, LA .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (01) :13-20
[8]  
BADHWAR GD, 1993, 23RD INTERNATIONAL COSMIC RAY CONFERENCE, VOL 3, P535
[9]  
Benton E V, 1983, Adv Space Res, V3, P171, DOI 10.1016/0273-1177(83)90188-6
[10]   DOSIMETRIC RADIATION MEASUREMENTS IN SPACE [J].
BENTON, EV .
NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1983, 7 (1-2) :1-11