VASCULAR OCCLUSION WITH A BALLOON-EXPANDABLE STENT OCCLUDER

被引:10
作者
MOSS, JG [1 ]
LABORDE, JC [1 ]
CLEM, MC [1 ]
RIVERA, FJ [1 ]
ENCARNACION, CE [1 ]
MEYER, KB [1 ]
PALMAZ, JC [1 ]
机构
[1] UNIV TEXAS,HLTH SCI CTR,DEPT CARDIOVASC & INTERVENT RADIOL,SAN ANTONIO,TX 78284
关键词
ANGIOGRAPHY; TECHNOLOGY; ARTERIES; THERAPEUTIC BLOCKADE;
D O I
10.1148/radiology.191.2.8153326
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effectiveness of a new vascular occlusion device. MATERIALS AND METHODS: The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. RESULTS: The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. CONCLUSION: This new occlusive device offers immediate vascular occlusion with excellent stability.
引用
收藏
页码:483 / 486
页数:4
相关论文
共 23 条
[1]   EVALUATION OF POLYMER-COATED BALLOON-EXPANDABLE STENTS IN BILE-DUCTS [J].
ALVARADO, R ;
PALMAZ, JC ;
GARCIA, OJ ;
TIO, FO ;
REES, CR .
RADIOLOGY, 1989, 170 (03) :975-978
[2]  
Becker G J, 1991, J Vasc Interv Radiol, V2, P225, DOI 10.1016/S1051-0443(91)72286-0
[3]  
Brooks B, 1931, TR SOUTH SURG ASS, V43, P176
[4]   COIL-IN-COIL TECHNIQUE FOR VASCULAR EMBOLIZATION [J].
BUTTO, F ;
HUNTER, DW ;
CASTANEDAZUNIGA, W ;
AMPLATZ, K .
RADIOLOGY, 1986, 161 (02) :554-555
[5]  
CASTANEDAZUNIGA WR, 1976, JAMA-J AM MED ASSOC, V236, P2649
[6]   EXPERIMENTAL VENOUS OCCLUSION WITH STAINLESS-STEEL SPIDERS [J].
CASTANEDAZUNIGA, WR ;
TADAVARTHY, SM ;
GALLIANI, CA ;
LAERUM, F ;
SCHWARTEN, DE ;
AMPLATZ, K .
RADIOLOGY, 1981, 141 (01) :238-242
[7]   COMPLICATIONS OF COIL EMBOLIZATION - PREVENTION AND MANAGEMENT [J].
CHUANG, VP ;
WALLACE, S ;
GIANTURCO, C ;
SOO, CS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (04) :809-813
[8]  
Duffy D M, 1990, Adv Dermatol, V5, P93
[9]   BALLOON EMBOLIZATION TO OCCLUDE A BLALOCK-TAUSSIG SHUNT [J].
FLORENTINE, M ;
WOLFE, RR ;
WHITE, RI .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :200-202
[10]  
KLEINERT JM, 1986, HAND CLIN, V2, P271