ON THE ORIGIN OF SOME CONTROVERSIAL IONS (M/Z 59, 60, 77, AND 119) IN THE THERMOSPRAY REAGENT PLASMA FROM AMMONIUM ACETATE

被引:14
作者
ABIAN, J
SANCHEZBAEZA, F
GELPI, E
BARCELO, D
机构
[1] CSIC,CID,DEPT BIOL CHEM,E-08034 BARCELONA,SPAIN
[2] CSIC,CID,DEPT ENVIRONM CHEM,E-08034 BARCELONA,SPAIN
关键词
D O I
10.1016/1044-0305(94)85032-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The origin of ions at m/z 60, 77, and 119 in the thermospray (TSP) reagent plasma is reconsidered. It is demonstrated that these major ions in the TSP spectrum of ammonium acetate are not due to dehydration processes in the gas or liquid phase, as is generally accepted, but to the preexistence of acetamide as an impurity in the commercial salts. Acetamide, characterized by TSP/tandem mass spectrometry, gas chromatography-electron impact ionization mass spectrometry, H-1-NMR, and C-13-NMR, is responsible for the [M + 60]+ and [M + 77]+ adducts observed in some spectra. The buffer ion at m/z 59 is also due to impurities in the ammonium acetate salts. Washing the solid salt with chloroform eliminates most of these impurities. Examples using the pesticides linuron, monuron, and carbaryl show that the ions observed at m/z M(r) + 60 and M(r) + 59 disappear when a buffer obtained from acetic acid and ammonia is used instead of the commercial salts.
引用
收藏
页码:186 / 193
页数:8
相关论文
共 10 条