CONTROLLED FORCE MEASUREMENTS OF GINGIVAL ATTACHMENT LEVEL MADE WITH THE TORONTO AUTOMATED PROBE USING ELECTRONIC GUIDANCE

被引:19
作者
KARIM, M [1 ]
BIREK, P [1 ]
MCCULLOCH, CA [1 ]
机构
[1] UNIV TORONTO, FAC DENT, DEPT PERIODONT, 124 EDWARD ST, TORONTO M5G 1G6, ONTARIO, CANADA
关键词
automated periodontal probe; electronic guidance system; gingival attachment level; probing angulation; reproducibility;
D O I
10.1111/j.1600-051X.1990.tb01111.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Abstract Precise reproduction of probe placement, probing force and probing angulation may influence the reliability of replicate gingival attachment level measurements (GAL). Reproducibility of GAL measurements was determined with the Toronto automated periodontal probe (TAPP) in which a novel electronic guidance system was incorporated to improve the precision of probing angulation. Bench testing of forces produced at the probe tip was performed with an electronic balance. Reproducibility and precision of force generation were tested in a variety of instrument configurations using laboratory models. The data indicated that highly precise and reproducible probing forces can be generated with the TAPP over a large (10 to 90 g) probing range. Instrument precision was ±0.27 mm when probing forces of 40–60 g were used. The guidance system provided accurate and reproducible measurements of the probe handle in both roll and pitch axes when compared with precisely machined wedges (R = 0.99, roll; R=0.98, pitch). Deviation of probing angulation greater than 5° on replicate measurements of GAL was associated with significant alterations in the location of circumferential probe placement and in the size of the difference between GAL measurements (ΔGAL). Clinical assessment of probing angulation in 6 patients demonstrated that ΔGAL was 0.40 ± 0.05 mm when probing angulation deviation was less than 5° but increased to 0.96 ± 0.11 mm when deviations exceeded 5°. Taken together, these data indicate that the regulation of probing angulation in clinical measurement of GAL with the TAPP is an important determinant of the reproducibility of periodontal probing. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:594 / 600
页数:7
相关论文
共 15 条
[1]   REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS [J].
BADERSTEN, A ;
NILVEUS, R ;
EGELBERG, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) :475-485
[2]   GINGIVAL ATTACHMENT LEVEL MEASUREMENTS WITH AN AUTOMATED PERIODONTAL PROBE [J].
BIREK, P ;
MCCULLOCH, CAG ;
HARDY, V .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1987, 14 (08) :472-477
[3]   MEASUREMENTS OF PROBING VELOCITY WITH AN AUTOMATED PERIODONTAL PROBE AND THE RELATIONSHIP WITH EXPERIMENTAL PERIODONTITIS IN THE CYNOMOLGUS MONKEY (MACACA-FASCICULARIS) [J].
BIREK, P ;
MCCULLOCH, CAG ;
OVERALL, CM .
ARCHIVES OF ORAL BIOLOGY, 1989, 34 (10) :793-801
[4]   DEPTH OF PERIODONTAL PROBE PENETRATION RELATED TO CLINICAL AND HISTOLOGIC SIGNS OF GINGIVAL INFLAMMATION [J].
CATON, J ;
GREENSTEIN, G ;
POLSON, AM .
JOURNAL OF PERIODONTOLOGY, 1981, 52 (10) :626-629
[5]  
De Waal H, 1986, J West Soc Periodontol Periodontal Abstr, V34, P5
[6]  
GABATHULER H, 1971, HELV ODONTOL ACTA, V15, P114
[7]   VALIDITY OF CLINICAL ASSESSMENTS RELATED TO THE CEMENTO-ENAMEL JUNCTION [J].
HUG, HU ;
VANTHOF, MA ;
SPANAUF, AJ ;
RENGGLI, HH .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (07) :825-829
[8]   A NEW PERIODONTAL PROBE WITH AUTOMATED CEMENTO-ENAMEL JUNCTION DETECTION [J].
JEFFCOAT, MK ;
JEFFCOAT, RL ;
JENS, SC ;
CAPTAIN, K .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1986, 13 (04) :276-280
[9]   ATTACHMENT LEVEL MEASUREMENTS WITH A CONSTANT FORCE ELECTRONIC PROBE [J].
MAGNUSSON, I ;
CLARK, WB ;
MARKS, RG ;
GIBBS, CH ;
MANOUCHEHRPOUR, M ;
LOW, SB .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) :185-188
[10]   COMPARISON OF GINGIVAL ATTACHMENT LEVEL MEASUREMENTS WITH AN AUTOMATED PERIODONTAL PROBE AND A PRESSURE-SENSITIVE PROBE [J].
MCCULLOCH, CAG ;
BIREK, P ;
HARDY, V .
JOURNAL OF PERIODONTAL RESEARCH, 1987, 22 (05) :348-352